User`s guide

USER'S GUIDE____________________________________________________________________
84 __________________________________________________________________ M211095EN-C
Items for Data Messages
The user-configurable data messages can contain wind measurement,
control character, check sum, and monitoring items. Configure new data
messages with the msg1, msg2, msg3, and msg4 parameters. All
available items are listed in Table 19 below, Table 20 below and Table
21 on page 85.
Table 19 Wind Measurement Items for Data Messages
Item Description
\ad Address
\dm Wind direction minimum
\dx Wind direction maximum
\gu Wind gust speed
\lu Wind lull speed
\rg Signal quality
\st Speed of sound
\Ts Sonic temperature
\va Validity of the measurement data. The available values are:
1 = valid wind measurement data
0 = unable to measure
\w1 Wind direction when the peak speed (wp) occurred
\wd Wind direction, average
\wm Wind speed minimum
\wp Wind speed, peak
\ws Wind speed, average
\wx Wind speed average, x component
\wy Wind speed average, y component
Table 20 Control Character and Check Sum Items for Data
Messages
Item Description
\01 SOH (start of heading)
\02 STX (start of text)
\03 ETX (end of text)
\04 EOT (end of transmission)
\cr CR (carriage return)
\lf LF (line feed)
\se Checksum calculation end point
\sp Print check sum
\ss Checksum calculation start point