User`s guide

Chapter 7 ________________________________________________________________ Operation
VAISALA _______________________________________________________________________ 93
protocol POLL command used or Automatic Message mode is used with
any protocol.
Table 23 WMT700 Data Messages
Data Message
Number
Description
WMT700 Data Messages
21 WMT700 profile message that reports average wind speed
and direction.
22 WMT700 profile message that reports wind speed in x and y
components.
23 WMT700 profile message that reports wind speed and
direction and self-diagnostics information.
24 WMT700 profile message that reports wind speed and
direction and self-diagnostics information, and includes the
checksum.
25 WMT700 profile message that reports wind measurement,
sonic temperature, and status data, and includes the
checksum.
27 ROSA - MES12 Standard profile message.
WS425 and SDI-12 Messages
15 WS425 A/B NMEA Extended profile message.
16 WS425 A/B ASCII profile message.
17 WS425 A/B SDI-12 profile message for M command.
18 WS425 A/B SDI-12 profile message for V command.
19 WS425 A/B NMEA Standard profile message.
User-Configurable Data Messages
1
2
3
4
Items defined by the user.
See User-Configurable Data Messages on page 83
To select a data message when using polling, specify the corresponding
data message identification number in the polling command. See section
POLL — Poll Data on page 103.
To select a data message when using automatic messages, use the
configuration parameters. See section Configuration Parameters on page
81.
Each of the predefined data m
essages of the WMT700 protocol is
described in more detail in sections below.
NOTE
For more information on user-configurable data messages, see section
User-Configurable Data Messages on page 83 in this manual.
For information on data messages of the WS425 and SDI-12 profiles, see
Upgrading from Vaisala WINDCAP
®
Ultrasonic Wind Sensor WS425 to
WMT70 Technical Reference.