Chapter 4 ________________________________________________________________ Operation
VAISALA_______________________________________________________________________ 53
Byte 5-7: Average wind direction (degrees) CR
LF
Bytes 8-10: Wind direction at peak wind speed
(degrees) CR LF
Bytes 11-12: Averaging time for wind speed and
direction CR LF
Bytes 13-14: Averaging time for peak wind speed
and direction CR LF
Bytes 15-19: Average wind speed CR LF
Bytes 20-24: Peak wind speed CR LF
Byte 25: Wind speed units (K = knots) CR LF
Byte 26-27: Signal quality CR LF
Bytes 28-29: Hex checksum CR LF
Byte 30: ETX CR LF
Byte 31: Carriage return CR LF
Byte 32 Line feed CR LF
WL Enable automatic heater control CR LF
WM Lock heaters on CR LF
WN Lock heaters off CR LF
WS Description of BIT status CR LF
WJ Set averaging times for wind speed/direction and peak
wind speed/direction CR LF
Enter password when prompted, then selections to the
following prompts CR LF
Wind speed/direction averaging time = ? CR LF
Peak wind speed and direction averaging time = ? CR LF
WD Perform and report extended diagnostic tests CR LF
WF Return fixed data in WA command format CR LF
WR Reset sensor CR LF
WCAL Perform Sensor Self Calibration CR LF
WH Display this help menu CR LF