Operating instructions

2
Operating Instructions
1. STOP! Read the safety information included
before proceeding.
2. Turn main valve knob to the OFF, full clockwise
position.
3. Place manual ON/OFF switch (if equipped) to the
O (OFF position).
4. Wait five (5) minutes to clear out any gas. Then
smell for gas, including near the floor. If you smell
gas STOP! Follow “A” in the safety information
above. If you don’t smell gas, proceed to step 5.
5. Turn MAN-knob (if equipped) to the ON, full
counterclockwise position (see figure 3).
6. Place manual ON/OFF switch in (ON position).
7. Simultaneously press and hold the (star) and
(up arrow) buttons (if Infrared Model: (star, up
arrow) and the small lower button) until a short
acoustic signal confirms the start sequence has
begun; release buttons. Continuing signals confirms
the ignition is in process. Once pilot ignition is
confirmed there is main gas flow. (see figures 4 & 5)
NOTE: If the pilot does not stay lit after several tries,
turn the gas control knob (main valve knob)
to OFF and proceed to step 9.
8. Set thermostat (if equipped) to desired setting or
use remote control to adjust flame. In standby mode:
press (up arrow) to increase flame height, press
(down arrow) to decrease flame height or set ap-
pliance at pilot flame. For fine adjustment tap the
up/down arrows.
9. If the appliance will not operate, follow the
instructions “TO TURN OFF GAS TO APPLIANCE
and call your service technician or gas supplier.
OPERATING INSTRUCTIONS MANUAL
IGNITION OPTION
(If equipped with optional MAN-Knob)
Follow appliance manufacturer’s instructions for gaining
access to the gas control and the pilot.
When turning main valve knob, do not force. Knob has a
slipping clutch, allowing for manual flame height
adjustment as well as adjustment to pilot standby
position.
1. STOP! Read the safety information included before
proceeding.
2. Turn main valve knob to the OFF, full clockwise
position.
3. Turn MAN-knob (if equipped) to the MAN, full
clockwise position.
4. Place manual ON/OFF switch (if equipped) to the
O (OFF position).
5. Wait five (5) minutes to clear out any gas. Then
smell for gas, including near the floor. If you smell
gas STOP! Follow “A” in the safety information
above. If you don’t smell gas, proceed to step 6.
6. Place manual ON/OFF switch in (ON position).
7. With the MAN-knob in MAN position a manual pilot
valve operator is accessible (see figure 2).
Fully push down manual pilot valve operator
and hold in, to start pilot gas flow.
Immediately light the pilot with a match,
while continuing to hold in the manual pilot
valve operator for about one (1) minute after
the pilot is lit. Release manual pilot valve
operator. If pilot does not stay lit, repeat
steps 2 through 8.
NOTE: If the pilot does not stay lit after several tries,
turn the gas control knob (main valve knob)
to OFF and proceed to step 11.
8. If applicable, per appliance manufacturer’s instructions,
replace pilot access panel before proceeding.
9. Turn MAN-knob to the ON, full counterclockwise
position.
When pilot ignition is confirmed, motor turns
automatically to maximum flame height.