Operating instructions

4
Operating Instructions
Maxitrol Company
23555 Telegraph Rd., Southfield, MI 48037
GV60-OI-EN-04.2006
www.mertikmaxitrol.com
Copyright © 2005 Maxitrol
Company All Rights Reserved
Location of Receiver
When the RF-receiver is placed in the appliance, the
surrounding metal can reduce reception considerably.
The position of the antenna on the receiver also
influences reception. The antenna must not come in
contact or cross the ignition wire.
Automatic Pilot Mode with Thermostat Remote
If there is no transmission from the handset to the
receiver within a 6 hour time period, the appliance will
go to standby (pilot) mode.
GENERAL NOTES
A code is preset for all Mertik Maxitrol electronics, but
can be changed if required. If you wish to change the
code, complete the following:
1. Change DIP switch position (see figure 6).
2. Press and hold the receivers reset button until you
hear two (2) acoustic signals. After the second longer
acoustic signal, release the reset button and within
the subsequent 20 seconds, press the (down
arrow) on the remote handset until you hear an ad-
ditional long acoustic signal confirming the new code
is set (see figure 7).
Figure 6: DIP Switch in Remote Handset
Battery Compartment
C. ADJUSTMENT - FLAME HEIGHT
INFRARED MODEL
To increase flame height press simultaneously ___
(star, up arrow) and the small lower button. There is a
separate button left for switching off (see figure 5).
NOTE: (Thermostatic Models) To save battery power,
press (down arrow) to turn main gas to
pilot gas. Press OFF button to shut off the
device including pilot flame. The device can
be shut off with the ON/OFF switch, thus dis-
abling the remote handset.
BATTERY REPLACEMENT
Battery replacement is recommended at the beginning
of each heating season. Batteries need to be changed
when an acoustic error message is heard. Do not use
metallic tooling. Metallic tooling could cause a short
that may render the receiver inoperable.
Receiver: ......................4 x 1.5V “AA”
(quality alkaline recom-
mended)
Remote Handset: .........1 x 9V
(quality alkaline recom-
mended)
An AC Mains Adapter may be used instead of batteries
(only the Mertik Maxitrol or an approved AC Mains
Adapter can be used).
NOTE: During a power outage the AC Mains Adapter
must be unplugged from the receiver to op-
erate in the battery mode.
Figure 5: Remote Handset, Infrared Model
Figure 7: Receiver with Reset button
Reset