Operating instructions

19
Appliance Preparation
Fasten Thermal Switch to
underside of burner module
using 2 existing screws
Optional Fan
(Blower)
If the Circulating Fan Kit (blower) is to be installed,
we suggest that you do it now.
1. Take the fan out of its package.
2. Remove the mounting plate from the fan and
discard it.
3. Position the fan in such a way that its exhaust
is directed upwards, towards the space
between the inner and the outer walls of the
rebox.
NOTE: You may need to remove the burner to
access the back of the stove. If this is the case,
rst remove the rear log support (NG/LPG)
and the front log support (LPG), and then, the
burner.
4. Using 3 screws, x the fan to the rebox bracket.
5. Fix the fan control box bracket provided to the
control box with 2 screws.
6. Fix the bracket, with the control box attached, to
the casting base of the stove from underneath.
7. With 2 screws from the burner plate, x the fan’s
thermoswitch to the underside of the burner
plate, behind the pilot area.
8. See instructions with the 555CFK kit for
complete details.
Fan control
box position
Fan control
box bracket
Once the gas pipe is tted, clip the receiver on top of the casting crossbar on the base,
to the left hand side of the valve. Make sure the receiver box is oriented with its wires
towards the back and its sensor at the front.
Receiver
Position
Receiver & clip Receiver clipped to crossbar in nal position