Front & Top Installation
Front
Installation
Hook the cast front to the side brackets located between the engine and the cast sides.
Cast front
Hook
Details
Engine
Side bracket
Air Shutter
Operation
Check
Aeration
Settings
Turn the replace ame up and down using the remote control to con rm that the full range
of inputs is achieved—see the remote control operation instructions on pages 29–32.
Light the re and allow the unit to warm up for 10–15 minutes to evaluate the ame
picture. The burner is equipped with an adjustable shutter to control primary aeration. See
the gures below. The shutter is factory-set to an aeration gap which will give optimum
performance for the vast majority of installations. In a few unusual installations, the ame
picture may be improved by adjusting the aeration. The need for adjustment should be
determined only by operating the appliance with the ceramic logs and window installed.
Increasing aeration will cause the ames to appear more transparent and blue making
the ceramic logs glow more.
Decreasing aeration will cause the ames to appear more yellow or orange making the
ceramic logs glow less.
Too little aeration may result in black carbon forming and dropping into the rebox.
Operation Check & Aeration Settings Adjustment
Flashback
shield (for
LPG only)
LPG Air Shutter
Slider
Open
Close
LPG
Open
Open
Close
Close
NG
NG Air Shutter
Slider & Cover