Unit installation

Fit the flue unit tubes firmly over the
spigots at the rear of the fire. Make sure that
the seam on the flue tube is NOT at the
bottom. Push on until the outer tube touches
the screw heads on the outer spigot (See
figure 12).
If it is felt of benefit, the flue unit may be
additionally secured to the fire with one or
two suitable self tapping screws (we suggest
No.6) before installing into the wall as
follows:-
Using a suitable metal cutting drill bit, drill
through the outer flue tube and outer spigot
at a distance of between 6mm & 7mm from
the cut end of the outer flue tube (See figure
12).
Fit the self tapping screw(s) in the drilled
hole(s).
Seal the flue unit all round the
circumference of the fire spigot with the tape
supplied.
Insert the plugs into the wall fixing holes. Insert the top right fixing screw leaving
the plain shank proud to allow the top fixing keyhole in the fire back to go over the
screw.
Offer the fire complete with flue unit through the wall and hook the top right
keyhole slot over the previously fitted wall screw.
Insert the top left and two bottom fixing screws and tighten.
Seal, the outer flue tube to the outside surface of the wall with fireclay or cement.
Make sure that the slots in the flue terminal are not closer than 8mm to the wall
and are not obstructed by cement.
Page 20
© Baxi Heating U.K. Limited 2010.
Figure 12. Flue securing.
INSTALLER GUIDE