Unit installation

17. SERVICING AND PARTS REPLACEMENT
This product uses fuel effect pieces and gaskets containing Refractory Ceramic
Fibres (RCF), which are man-made vitreous silicate fibres. Excessive exposure
to these materials may cause irritation to eyes, skin and respiratory tract.
Consequently, it is important to take care when handling these articles to
ensure that the release of dust is kept to a minimum. To ensure that the release
of fibres from these RCF articles is kept to a minimum, during installation and
servicing we recommend that you use a HEPA filtered vacuum to remove any
dust and soot accumulated in and around the fire before and after working on
the fire. When replacing these articles we recommend that the replaced items
are not broken up, but are sealed within a heavy duty polythene bag, clearly
labelled as RCF waste. RCF waste is classed as a stable, non-reactive
hazardous waste and may be disposed at a landfill licenced to accept such
waste. Protective clothing is not required when handling these articles, but we
recommend the use of suitable gloves to prevent irritation. We also recommend
you follow the normal hygiene rules of not smoking, eating or drinking in the
work area and always wash your hands before eating or drinking.
This appliance does not contain any component manufactured from asbestos
or asbestos related products.
Turn off the gas and make sure that the appliance is completely cool before
commencing any servicing.
Always test for gas soundness after refitting the appliance.
17.1 To remove the fascia.
Remove the knurled screws and washers at the fascia sides (See figure 1).
Pull the bottom of the fascia forward and lift clear.
17.2 To remove the window unit.
Remove the fascia as in section 17.1.
Remove the window unit by detaching the 12 wing nuts securing the frame and
pulling forward (See figure 5).
17.3 To remove the ceramic fuel effect.
Remove the fascia as in section 17.1.
Remove the window unit as in section 17.2.
Remove the ceramic coals carefully.
Lift out the ceramic coal base.
Replace the items as described in section 12 of this guide.
Page 28
© Baxi Heating U.K. Limited 2010.
INSTALLER GUIDE