Unit installation

To select the burner setting.
When the pilot is alight, partially depress the knob and turn to position 1. Both
main and decorative flame burners should light at their lowest setting. The decorative
flames should just be visible.
Turn the control knob gradually to your desired setting. Both burners should
gradually increase in output until at MAX position the main burner is at its greatest
heat output and the decorative flames are at their full magnitude.
To turn off
To turn the main and decorative flames off but leaving the pilot alight, depress the
control knob partially, turn clockwise to IGN and release the knob. If any resistance is
felt at position 1 when turning, release the downward pressure on the knob before
continuing to turn.
To turn the pilot off, depress the control knob at the IGN position, turn clockwise to
OFF and release the knob.
CLEANING YOUR FIRE
All cleaning should be carried out when the fire is OFF and has been allowed to
cool completely. Normally, the fire should only need dusting. Any stains on the glass
can be removed with a non-abrasive cleaner such as a ceramic hob cleaner. Abrasive
cleaners should never be used.
To clean the inside of the window.
Detach the fascia by removing the knurled screws
and washers at the fascia sides (See figure 2).
Pull the bottom of the fascia forward and then lift to
remove.
Remove the window unit by detaching the 12 wing
nuts securing the frame (See figure 5) and pulling
forward.
Clean the window carefully using a suitable cleaner
in accordance with the instructions supplied with the
cleaner.
Replace the window unit ensuring that the seal
around the frame is not damaged or misplaced.
Secure with the 12 wing nuts tightening them evenly.
Replace the fascia.
Page 37
© Baxi Heating U.K. Limited 2010.
Figure 5. Window removal
OWNER GUIDE