Manual
PAGE 4
2950 Mechanic Street
Lake City, PA 16423-2095
Phone: 800/840-9906
Fax: 814/774-3482
www.vanairsystems.com
CONDITION
Initial pressure
drop too
high
Oil carryover
Short element
life
POTENTIAL CAUSE
Filter undersized for ow rate.
Filter grade too ne.
Filter inlet smaller than pipe size.
Oil present in system before installing lter.
Excessive inlet oil > 50ppm.
Filter installed backwards.
Filter bowl not being drained.
High differential pressure.
Defective seal.
Incorrect replacement element.
By-pass valve leaking or open
Unltered air entering from source down stream of lter.
High operating temperatures.
Cooling by refrigerated dryer.
Excessive particulate contamination.
High compression temperatures causing varnish/carbon
formation.
Oil water emulsion overloading element.
High viscosity oil or freeze-up due to low ambient tem-
perature.
RECOMMENDATION
Install larger lter.
Install coarser grade element.
Install larger lter.
Clean piping.
Check compressor and/or air/oil separator if compressor is rotary vane
or screw. Lower lube rate if reciprocating compressor. Install coarse
coalescer for preltration.
Check installation instructions.
Check and repair auto drain. Drain frequently if manual valve.
Check element if excessive (7-10 psid or above).
Check o-ring in element.
Check and use ner grade.
Close valve. Check seals.
Relocate lter or install additional lter.
Install, clean, replace or relocate aftercooler.
Install grade B or C lter downstream of dryer.
Install coarse coalescing lter immediately upstream of existing lter.
Use compressor lubricant with good temperature stability. Lower lube
rates where possible. Use coarser grade lter element.
Inspect separator. Remove water with better separation.
Raise ambient temperatures. Heat trace inlet piping and housing.
TROUBLESHOOTING