Owner's manual

REV 2 CT-7500 S2 USER’S MANUAL
72
3.3.3. Recalling a Test Record from the Flash EEPROM
Follow the steps below to recall a test record from the CT-7500 S2’s Flash EEPROM:
a. Start from the “START-UP” menu:
Press the [3] key (SETUP).
b. The following screen will be displayed:
Press the [3] key (SAVE / RESTORE)
c. The following screen will be displayed:
Press the [2] key (RESTORE SHOT).
d. The following screen will be displayed:
Using the keypad, type the record number that you would like to restore. If you do not
know the record number, you can first print a test record directory using the
instructions in section 3.3.2. Press the [ENTER] key.
e. A confirmation screen will be displayed with some details about the selected test as
shown below:
Press the [ENTER] key.
RESTORING SHOT #1
TEST: STATIC RES
DATE: 03/11/10 13:26
“ENTER” TO CONFIRM
ENTER SHOT NUMBER
TO BE RESTORED
“ENTER” TO CONFIRM
1. SAVE SHOT
2. RESTORE SHOT
3. SHOT DIRECTORY
4. ERASE SHOT
1. ANALYSIS POINTS
2. MEASUREMENT UNITS
3. SAVE / RESTORE
4. NEXT PAGE
1. TIME BRKR 02/10/11
2. GET RSLT 09:04:05
3. SETUP
4. DIAGNOSTICS