Product Specifications

KHSLD LINER Equipped with LED GU10 lighting. Not available with heat lamps. Available in Black,
Biscuit, Gunsmoke Gray, Stainless Steel, or White.
WALL MOUNT LINER INSERT SPECIFICATIONS
Top Vent or Back Vent
3 ¼” x 10”
The VP521 transition is available
for top vent applications
at an additional charge.
Cutout for Vertical Ducting
Viewed from Above
Back of
Liner
5 ⁄"
C
L
5 ⁄"
6 ¼"
Electrical
3 ½"
⁄"
2 ⁄"
Wall Cutout for Horizontal Ducting
Viewed from Front
Top of Liner
5"
5 1⁄8" 7"
C
L
*Recommended mounting
height is for optimum
performance.
U
L
CUS
R
7”
7 ½”
3 ¼”
10”
Connection Diagrams (28 3/8", 34 3/8", & 40 3/8" Widths) Recommended
Mounting Height*
KHSLD
Electrical/Mechanical Specications For Blower Units
Model Volts Amps Hz RPM
CFM
SP@0.0"
Equivalent CFM
CFM
SP@0.1"
CFM
SP@0.2"
CFM
SP@0.3"
Minimum Round
Duct Size
Sones
#
K250 (Top Vent) 115 3.5 60 1550 250 375 223 220 190 7" (38 in.
2
) 7.4
K250 (Back Vent) 115 3.5 60 1550 220 330 215 195 180 7" (38 in.
2
) 7.4
Equipped with two LED GU10 lights.
• BecausethePowerLung
®
blowerusescentrifugalltrationratherthanconventionalbafeormeshlters,thePowerLung
®
blowercanhandlecookingequipmentwithhighercubicfeetperminute(CFM)requirementsandcandeliverequivalentCFMmuchmore
efcientlythanotherltrationsystems.WhencomparingthePowerLung
®
withotherblowerunitsmadebyothermanufacturers,usethe“EquivalentCFM”.
# RatingsinaccordancewiththeStandardTestCodebytheEnergySystemsLaboratoryoftheTexasEngineeringExperimentStation.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 1218A








