Install Guide

1313
1 2 3
Terminal Block
Smaller opening
Strain relief bracket
Fig. 3.1
L1
N
L2
PE
Fig. 3.2
L1 N L2
PE
Fig. 3.3
2
PERMANENT CONNECTION (HARD WIRING)
US only, for Canada it is mandatory to connect the range by
using cordset with plug supplied.
Units may be hard wired to the power supply. The installer
must provide approved exible aluminium conduit, 3/4”
(19mm) trade size, maximum 6ft (1.8m) long. Locate the
terminal block on the rear of the unit and remove access
cover.
The strain relief bracket orientation must be so that the 1 1/8”
(29mm) smaller opening is facing down (fig. 3.1). If not, the
strain relief bracket orientation must be switched in order to
accommodate for a permanent wiring connection:
1. If fitted, remove the factory supplied power cord with
plug.
1. Remove the 2 screws on the bracket.
2. Re-secure bracket with the 2 screws so that the 1 1/8”
(29mm) smaller opening is facing down.
The conduit must be installed to the terminal block using
an approved conduit connector. The free end of the conduit
must be connected to a junction box provided in the electrical
supply zone.
Mount a strain relief (not provided) into the 1 1/8”
(29mm) diameter hole located below the terminal block.
Wiring for the unit is to be brought into the terminal block
through the conduit and through the strain relief. Make
suitable connections to the terminal block provided.
Installer — Show the owner the location of the circuit breaker.
Mark it for easy reference.
4-Wire Installation (fig. 3.2)
1. Loosen the L1, L2 and neutral screws.
2. Mount the conduit fitting to the 1 1/8” (29mm) hole in the
strain relief bracket.
3. Secure the neutral power lead to the center terminal and
tighten the screw.
4. Secure the L1 and the L2 power leads to the terminals
immediately to the left (L1) and right (L2) of the neutral
terminal. Tighten the screws.
5. Secure the Ground lead to the green screw located to the
right of the terminal block using the supplied cupped washer.
The end of the grounding conductor must be retained by the
cupped washer.
6. Check all connections are securely tightened.
7. Reinstall the Terminal Block cover.
3-Wire Connection (using supplied Ground lead)
(fig. 3.3)
1. Loosen the L1, L2 and neutral screws.
2. Mount the conduit fitting to the 1 1/8” (29mm) hole in the
strain relief bracket.
3. Secure the supplied Ground lead to the grounding screw to
the right of the terminal block.
4. Secure the Neutral power lead together with the free end of
the Ground lead to the center terminal. Tighten the screw.
5. Secure the L1 and the L2 power leads to the terminals
immediately to the left (L1) and right (L2) of the neutral
terminal. Tighten the screws.
6. Check all connections are securely tightened.
7. Reinstall the Terminal Block cover.
WARNING
DO NOT FIT A 3-PRONG PLUG