Install Guide

1414
3
Before any operation of maintenance
disconnect the appliance from the
electrical main supply.
RANGES SUPPLIED WITH POWER CORD (WITH PLUG)
ALREADY FITTED
If codes permit and a separate ground wire is used, it is recommended that a
qualied electrician installer determine that the ground path and wire gauge are in
accordance with local codes.
Be sure that the electrical connection and wire size are adequate and in conformance
with:
ANSI/NFPA 70 latest edition and local codes and ordinances;
CSA Standard C22.1, Canadian Electrical Code, Part 1 - latest edition, and all local
codes and ordinances.
ONLY FOR CANADA:
A copy of the above code standards can be obtained from:
CANADIAN STANDARDS ASSOCIATION
178 Rexdale Boulevard
TORONTO, ON M9W 1R3
CANADA
Do not ground to a gas pipe.
Check with a qualied electrical installer if you are not sure the range is properly
grounded.
Do not have a fuse in the neutral or ground circuit.
When a 4-wire, two phase 240-208/120-volt, 60Hz, AC-only electrical supply is
available, a 30 amp maximum circuit protection is required, fused on both sides of
the line.
A time-delay fuse or circuit breaker is recommended.
This range is equipped with a Certied Power Cord intended to be plugged into
a standard 14-50R wall receptacle. Be sure the wall receptacle is within reach of
range’s nal location.
Do not use an extension cord.
In the case of substitution of the power cord always replace it with a suitable UL or CSA
approved one (with the same technical features of the replaced cord).
Tighten the power cord by using only the power cord strain relief bracket supplied with
the appliance.
Allow enough slack to easily attach the cord terminals to the terminal block.
These operations must be carried out only by an authorized technician.
Electrical Shock Hazard
Plug into a grounded outlet.
Do not remove ground prong.
Do not use an adapter.
Failure to follow these
instructions can result in death,
re, or electrical shock.
Power supply cord with
NEMA 14-50P plug
Standard NEMA 14-50R wall receptable
Fig. 3.4
IMPORTANT!
The fourth (ground) prong
should not, under ANY
circumstances, be cut or
removed.