Installation Manual

EN
7
3-Wire Branch Circuit (For Us Only)
Refer to Figure A, where local codes allow the connection of
GROUND wire from the oven to the branch circuit NEUTRAL
wire(grayorwhitecoloredwire):
• If local codes permit, connect the green GROUND wire
from the oven and the white wire from the oven to the
branchcircuitNEUTRALwire(grayorwhitecoloredwire).
• Connect the red and black leads from the oven to the
corresponding HOT Wires in the junction box.
• Connect the local codes and power supply codes using a
terminal.
• The terminal uses a thing adapting to the wire of the cord.
GROUNDED NEUTRAL
White wires
Cable from
power supply
Junction box
UL listed conduit
connector
Red wires
Black wires
Cable
from oven
Bare or
green wire
A
4-Wire Branch Circuit (For Us And
Canada)
Refer to Figure B:
• Disconnect ground from neutral at free end of conduit.
• Connect the green GROUND wire from the oven to the
GROUNDwireinthejunctionbox(bareorgreencolored
wire).
• Connect the red and black leads from the oven to the
corresponding HOT Wires in the junction box.
• ConnectthewhitewirefromtheoventotheNEUTRAL(gray
orwhite)wireinthejunctionbox.
• Connect the local codes and power supply codes using a
terminal.
• The terminal uses a thing adapting to the wire of the cord.
UNGROUNDED NEUTRAL
Red wires
Junction box Cable from
power supply
White wires
Black wires
UL listed conduit
connector
Cable
from oven
Bare or
green wire
B
Electrical Connections
Be sure your appliance is properly installed and grounded by a qualied technician. Ask your dealer to recommend a qualied
technicianoranauthorizedrepairservice.
This appliance is manufactured with a green GROUND wire connected to the oven chassis. After making sure that the power has
been turned o, connect the exible conduit from the oven to the junction box using a U.L. listed conduit connector. Figures A and B
and the instructions provided below present the most common way of connecting the ovens.
Your local codes and ordinances, of course, take precedence over these instructions. Complete electrical connections according to
localcodesandordinances“WARNING”RiskofElectricShock,framegroundedtoneutralofappliancethroughalink.
Grounding through the neutral conductor is prohibited for new branch-circuit installations (1996 NEC); mobile homes; and
recreational vehicles, or in an area where local codes prohibit grounding through the neutral conductor. For installations where
grounding through the neutral conductor is prohibited:
• Disconnectthegroundfromtheneutralatfreeendofconduit;
• Usegroundingterminalorleadtogroundunit;and
• Connect neutral terminal or lead to branch circuit neutral in usual manner.