Operating Instructions

Mopeka Products LLC www.mopeka.com
M2000003A
Manuel & Operating Instructions
Standard Sensor Models M2008 (Propane)
INTENDED USE OF THE M2008 SENSOR IS TO MEASURE THE AMOUNT OF LIQUID PROPANE INSIDE A PROPANE
TANK MEETING THE SPECIFATIONS BELOW, UNDER THE CONDITIONS LISTED BELOW.
THIS DEVICE IS INTENDED FOR OUTDOOR USE ONLY.
WARNING
USE OF THIS DEVICE IN A MANNER OTHER THAN STATED IN THIS MANUAL, MAY RESULT IN IMPAIRMENT OF
THE DESIGNED SAFETY PROTECTION AND THUS AN UNSAFE CONDITION.
SPECIFICATIONS
MEASUREMENT METHOD
Ultrasonic
FLUID
Propane
TANK TYPES
Steel Tanks
Note: Also works with aluminum tanks with alternate mounting.
Not intended for use on composite cylinders.
TANK SIZES
Vertical DOT Cylinders of 20 -100 lb (5 - 25 gal)
Horizontal tanks up to 11’ diameter
Envelope Dimensions
97 x 61 x 17.2 mm (3.8 x 2.4 x 0.68 in)
Mounting location
Tank Bottom
Suitable for these locations
CLASS 1, DIVISION 2, GROUP D
CLASS 1, ZONE 2, GROUP IIA
OPERATING TEMPERATURE RANGE
-40° TO 60°C
TEMPERATURE CODE
T6
BATTERY
2 AA (non replaceable)
HUMIDITY RANGE
0 - 100%
MAX ALTITUDE
4000m
AMBIENT CONDITIONS FOR TESTING
23°C, 14.7 PSIA
WARNING
THIS DEVICE IS NOT TO BE REPAIRED OR OTHERWISE MODIFIED.
MOPEKA PRODUCTS LLC
MAILING ADDRESS: 445 FM 1983, COLORADO CITY, TX 79512
www.mopeka.com