Technical data

48
1 Fuel system
Drain the water from the water separator/
fuel filter and the fuel tank. Ensure that the
tank is completely filled with fuel.
Running with protective fuel mixture
Connect the fuel supply pipe to a can filled
with a mixture of one (1) part of engine oil*
to nine (9) parts of clean fuel**. Use this
mixture to run the engine at no load for
approx. 10 minutes.
Stop the engine.
* Engine oil with protective properties.
E.g. Shell Super Diesel T 10W40
** Preferably water-free fuel.
Collect some fuel from the return pipe,
while engine is running.
Neverruntheengineunderloadwiththis
mixture of fuel and oil.
5 Winter storage procedure
VD01006 VD00136