WIRING DIAGRAMS
WIRING DIAGRAMS
1 & 2 Section 208-240 Volt Warmer Wiring Diagram
45
YEL
WHT
BRN
FAN
17
3
BLU
2
15
BLOWER
4
HEATERS
WHT-HT
WHT-HT
WHT
RED
1
NOTES:
2
RED
REPRESENTS CONNECTION
AT TERMINAL BLOCK
1
8
76
WHEN DOOR IS CLOSED CONTACT MAKES
WHICH OPENS THE LIGHT RELAY. WHEN
DOOR IS OPEN CONTACT BREAKS WHICH
CLOSES THE LIGHT RELAY.
MAGNETIC CONTACT
V-TEMP CONTROL
CABINET
1
W
W
LIGHT
13
LIGHT RELAY
BLK
RED
1
L
CONTROL
CIRCUIT
N
1819
2
2
BLK
208-240/1/60
HTR RELAY
21
HTR
BLK
WHT
CABINET
LIGHTS
HEATER SAFETY
THERMAL SWITCH
1 & 2 Section 115 Volt Warmer Wiring Diagram
7
WHEN DOOR IS CLOSED CONTACT MAKES
WHICH OPENS THE LIGHT RELAY. WHEN
DOOR IS OPEN CONTACT BREAKS WHICH
CLOSES THE LIGHT RELAY.
MAGNETIC CONTACT
1
W
W
6
CABINET
45
8
RED
YEL
WHT
BRN
FAN
17
3
BLU
2
15
BLOWER
4
HEATERS
WHT-HT
WHT-HT
WHT
RED
1
NOTES:
2
WHT
REPRESENTS CONNECTION
AT TERMINAL BLOCK
1
V-TEMP CONTROL
LIGHT
13
LIGHT RELAY
BLK
1
L
CONTROL
CIRCUIT
N
1819
2
2
BLK
115/1/60
HTR RELAY
21
HTR
BLK
WHT
CABINET
LIGHTS
HEATER SAFETY
THERMAL SWITCH