CMOR Professional Dome User Manual Product ranges covered by this manual CMOR Classic: Vi-D118, Vi-D126 and CMOR Evolution: Vi-D218, Vi-D228, Vi-D236 Vi-ALM1 Vi-PSU-1 Options Document Reference Date Firmware Vc601i.doc 14/02/2010 From Vc001A92/Vc005b01 Videoswitch Telephone 01252-851510 Ocean House, Redfields Industrial Park Fax 01252-851296 Redfields Lane, Church Crookham Email sales@videoswitch.co.uk Hants GU52 0RD Web www.videoswitch.co.uk Videoswitch Page 1 Vc601i.
Contents 1 Configuring the Dome..............................................1 1.1 CMOR Evolution Configuration ..............................................................................................1 1.1.1 Auto-Protocol and Auto-Baud ............................................................................................1 1.1.2 Address ..............................................................................................................................1 1.1.3 Reset Address ....
IR..........................................................................................................................................26 5.4 5.4.1 IR Mode ...........................................................................................................................26 5.4.2 IR ON level.......................................................................................................................26 5.4.3 IR Off level hysteretic...................................................
CMOR Dome 1 Configuring the Dome 1.1 CMOR Evolution Configuration 1.1.1 Auto-Protocol and Auto-Baud No DIP switch configuration is necessary if the DIP switches are left in their default configuration (all switches OFF except for 6-way DIP switches section 6 ON). Some Evolution domes do not have switches fitted. The CMOR Evolution will automatically detect the protocol and the baud rate.
CMOR Dome 1.1.4 Termination • If you are using a star expander (eg. Videoswitch Vi-E2) to drive multiple domes (which is the recommended method) all domes should be have termination ON. • If you are using an alarm module, termination in the dome should also always be ON. • If you are daisy-chaining domes, for all except the last in the daisy chain, you will need to turn the termination of the alarm module OFF (if fitted) or else turn the termination of the dome OFF.
CMOR Dome Videoswitch Page 3 Vc601i.
CMOR Dome 1.2.2 Setting the dome address • Set the 8-way switch (A) to the required address (camera number) of the dome as per the table below. “0” represents OFF (down) and “1” represents ON (up).
CMOR Dome Dome Address 8 Dome Address 8-way DIP switch 1 2 3 4 5 6 7 8 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 8-way DIP switch 2 3 4 5 6 7 8 Dome Address 8-way DIP switch 1 2 3 4 5 6 7 8 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 80
CMOR Dome Dome Address 8 Dome Address 8-way DIP switch 1 2 3 4 5 6 7 8 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 8-way DIP switch 2 3 4 5 6 7 8 Dome Address 8-way DIP switch 1 2 3 4 5 6 7 8 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 1 1 1 1 1 1 1 1 1 1
CMOR Dome Dome Address 8 Dome Address 8-way DIP switch 1 2 3 4 5 6 7 8 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 8-way DIP switch 2 3 4 5 6 7 8 Dome Address 8-way DIP switch 1 2 3 4 5 6 7 8 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 1 1 1 1 1 1 1 1 1 1
CMOR Dome Dome Address 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 1 8-way DIP switch 2 3 4 5 6 7 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 Videoswitch 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 8 Dome Address 8-way DIP switch 1 2 3 4 5 6 7 8 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254
CMOR Dome 1.2.3 Setting the dome protocol • Set sections 1,2 and 3 of the 6-way switch (B) as per the table below to select the required protocol. “0” represents OFF (down) and “1” represents ON (up).
CMOR Dome 1.2.5 Setting the RS485 termination Set section 6 of the 6-way switch (B) as per the table below to select the termination of the RS485 twisted pair input. “0” represents OFF (down) and“1” represents ON (up). The default position in ON (up).
CMOR Dome Videoswitch Page 11 Vc601i.
CMOR Dome 2 Installing the Dome These installation instructions assume that a standard wall-mount bracket is being used. For swan-neck, pendant and corner options, refer to their specific instruction sheet. 2.1 Fixing the mounting ring or plate • Fix the mounting ring to the wall using four screws (A) of adequate size and strength to support the weight of the dome and bracket. • Fit the umbilical cable, entering either through the wall or via a cable gland as illustrated below.
CMOR Dome 2.2 Securing the bracket • Secure the bracket (B) to the mounting plate (A) using the 4 screws supplied (C) • For safety reasons, one of the fixing screws must have washer (D) fitted as shown below. • Position the umbilical cable (E) such that the connector (F) is above the dome support cradle (G) Videoswitch Page 13 Vc601i.
CMOR Dome 2.3 Attaching the CMOR Dome • Fully loosen the locking ring (C) by rotating clockwise until it nearly touches the top of the dome • Lift the dome (taking care not to lift it using lamps) and place the dome support plate (A) onto the dome support cradle (B). Note that the curved side of the support plate goes to the back. • Rotate the locking ring (C) counter-clockwise to lock the dome firmly in position. 2.
CMOR Dome 2.5 Fitting the bracket cover • Locate the two plastic sides of the cover on the metal support bracket • Fix together with the supplied screw using the supplied Allen key Videoswitch Page 15 Vc601i.
CMOR Dome 3 Installing Power Supply The CMOR-PSU-1 power is supplied in a weatherproof box that may be mounted externally or internally. 3.1 Fixing power supply to wall • Fit the optional alarm module (A) into the power supply using the 4 screws provided. • For safety reasons never remove the slotted metal cover (B). • Fix the power supply to a wall using a screw in each of the four corner holes (C). Videoswitch Page 16 Vc601i.
CMOR Dome 3.2 Power Supply Connections 3.2.1 Mains Input Identification Mains Power Live Live (brown) 240Vac 50Hz Neutral Neutral (blue) 240Vac 50Hz Earth Earth (Yellow/Green) 3.2.2 Connections to dome Identification Umbilical lead to dome CAM2 White Coax signal (dual camera version only) GND White Coax screen (dual camera version only) CAM1 Black Coax signal GND Black Coax screen RS485 (A) WHITE RS485 (B) ORANGE +24V RED 0V BLACK and Cable screen 3.2.
CMOR Dome GND CAM1* Camera input GND RS485 (A) RS485 (A) or (+) dome output RS485 (B) RS485 (B) or (-) dome output Spare Not connection GND RS485 ground Identification DVR CAM2 (BNC)* DVR camera input (dual camera version only) CAM1 (BNC)* DVR camera input CAM2 (BNC) Loop-through provided for test monitor (dual camera version only) CAM1 (BNC) Loop-through provided for test monitor *Note that the video connection(s) made be made either using the BNC or the screw terminals, whichever is mo
CMOR Dome 3.3 Alarm Module Connections 3.3.1 Alarm Inputs Identification Alarm Inputs 1 2 3 4 5 6 7 8 9 Connect to NO or NC relay contact of PIRs or other alarm sources. 10 11 12 13 14 15 16 3.3.2 Alarm Grounds All alarms grounds are connected together and any may be used for the relay common outputs of the PIRs or other alarm sources. 3.3.
CMOR Dome 4 Configuring the Alarm Module 4.1 Normally Open or Closed Alarm Inputs Set section the switch identified “NO/NC” as per the table below to select whether all the alarm inputs are connected to sensors with normally open or normally closed outputs. “0” represents OFF (down) and“1” represents ON (up). The default position in ON (up).
CMOR Dome 4.4 Setting the alarm module baud rate • Set sections 5 and 6 of the DIP switch as per the table below to select the required baud rate. “0” represents OFF (down) and “1” represents ON (up). • The default setting is 9600 baud (both switches OFF) • PelcoD normally uses 2400 baud • PelcoP normally uses 4800 baud Baud rate 5 6 9600 2400 4800 19200 0 1 0 1 0 0 1 1 The alarm module baud rate should be set to be the same as the dome baud rate. Videoswitch Page 21 Vc601i.
CMOR Dome 5 Menus 5.1 Menu Navigation 5.1.1 Entering Menu Different keyboards have different ways of entering the menu system of a dome. Refer to specific keyboard manual for details. Common examples are: • Videoswitch Vi-K2 Press DOME then press MENU • Videoswitch Vi-K3 Press and hold ALT then press DOME MENU • BBV (TX400) Press and hold SHIFT then press 1 • Pelco (KBD300A) Enter 95 then press and hold PRESET key • DS2 Press and hold * 8,8,910,10,2 5.1.
CMOR Dome 5.1.5 Exit Menu Leave the menu by going LEFT out of all levels until you leave the menu. Alternatively, use the same key combination that was used to enter the menu. The menu will also exit automatically if not used for 5 minutes. All changes made will be saved permanently when the menu has been exited. The message “Saved OK” will flash up on the screen to confirm this The various branches of the menu system are described below.
CMOR Dome 5.3 Setup Use this sub-menu to select general dome configuration settings as below: 5.3.1 Enter date/time Use UP, DOWN, LEFT and RIGHT to set the date and time. The format is DD/MM/YY HH:MM:SS. Move cursor LEFT to exit. 5.3.2 Daylight Saving Default setting is AUTO which is suitable for use in Europe. Alternatively set to WINTER for no time change, or to SUMMER to advance the displayed time by one hour. 5.3.3 Language The language used in the menu and for other messages is selected here. 5.3.
CMOR Dome The default password 111100 may be changed if required. Take care to make a note of the new password. 5.3.6 Datum Check The dome can be set to perform a datum check every 24 hours, at midnight. This means that the dome will pan and tilt for a few seconds while it performs a self test and checks its alignment. It will revert to an existing preset or tour when the process is complete. It is recommended that the 24 hour option is selected (default) 5.3.
CMOR Dome 5.4 IR Options relating to the built-in Infra Red (IR) lamps are set in this sub-menu. 5.4.1 IR Mode This option determines when the IR lamps are turned on: Light sensing (default) - the lamps turn on automatically when it gets dark Timed - the lamps turn on according a time of day schedule Manual - the lamps turn on and off under manual control 5.4.2 IR ON level Set this number to specify the light level at which the IR lamps turn on.
CMOR Dome 5.5 Camera 5.5.1 Main camera settings 5.5.1.1 Video Gain The video gain may be set from 0 to 7 to compensate for losses in long cable runs. Default is 0. 5.5.1.2 Video Lift The high frequency video lift may be set from 0 to 8 to compensate for losses in long cable runs. Default is 0. 5.5.1.3 Digital Zoom This option selects whether you want to be able to zoom beyond the optical zoom limit and use digital zoom. The default setting is OFF. 5.5.1.
CMOR Dome 5.5.1.5.3 Joystick Focus There are two settings; Auto & Manual. The default setting for NIGHT is Manual. 5.5.1.5.4 Preset Focus Mode There are two settings; Auto & Stored. The default setting for NIGHT is manual. 5.5.1.5.5 Zoom Limit 5.5.1.5.6 Backlight Compensation 5.5.2 Context Camera 5.5.2.1 Not available 5.5.3 Invert Image This inverts the image. This option is used only if the dome is mounted upside down. 5.
CMOR Dome 5.6.6 Pan Limits 5.6.6.1 Use Pan Limits If you wish to stop the dome from panning all the way round, for example if it is mounted on a wall or corner, set this option (after you have set the right and left limits). Once set, the dome will stop if it is panned up to a limit. When moving between presets, the dome will also stay in the permitted zone rather than taking the shortest route as it would otherwise. 5.6.6.
CMOR Dome • Calling up a preset • An alarm 5.8.1.1 Tour 1 (to Tour 8) 5.8.1.1.1 Title If you want a title to be displayed when you select a tour, enter it here. Otherwise the default T1, T2, T3 etc will be displayed. 5.8.1.1.2 Initialise Tour Use this option to initialise a tour as follows: • Set Fill the tour with presets. Presets that are not set will be ignored. As more presets are programmed, they will automatically be included in the tour.
CMOR Dome 5 Move joystick/arrow key right 6 Move camera to required view 7 Select OK (Vi K/B) or 01+preset (Pelco K/B), or Preset, 10 ,1 (on DS2) or wait 15 seconds until a red mask patch appears Red mask patch appears 8 Scroll to next MASK number (using arrow keys or joystick UP/DOWN) Blue mask patch appears 9 Move joystick or arrow key to the RIGHT Cross lines appear 10 For each new mask position, repeat steps 4 to 7 12 When all mask positions have been created , exit menus & save by movin
CMOR Dome 6 Technical Data 6.1 Vi-D1 Classic and Vi-D2 Evolution Domes 6.1.1 Camera Sony Ex-View Had ¼” CCD 18:1, 26:1 or 36:1 optical zoom and optional 12:1 digital zoom 6.1.2 IR Illumination Double-hetero AlGaAs LEDs 830nm wavelength (optional 940nm fully covert) Degradation estimated at 3% per year (not guaranteed) 6.1.3 Power requirements 24V DC, 2.5Amps Maximum 6.1.
CMOR Dome 6.3 Vi-ALM1 Alarm Module 6.3.1 Alarm Inputs/Outputs 16 inputs, suit normally open or normally closed triggers 1 change over relay output for signally to DVR 6.3.2 Physical and Environmental Environmental IP66 when fitted in PSU) 6.4 Brackets and Cables 6.4.1 Vi-B2 Wall bracket 6.4.2 Vi-B5 Corner adaptor 6.4.3 Vi-B4 Swan-neck bracket 6.4.4 Vi-B3 Pendant bracket 6.4.5 Vi-B6 Pole mount bracket 6.4.6 Vi-B7 Dome adaptor 6.4.7 Vi-B8 Ceiling Mount Kit 6.4.
CMOR Dome Serial Number of dome Notes Notes Videoswitch Page 34 Vc601i.