Instruction Manual

CMOR Dome
Videoswitch Page 9 Vc601i.doc
1.2.3 Setting the dome protocol
Set sections 1,2 and 3 of the 6-way switch (B) as per the table below to select the
required protocol. “0” represents OFF (down) and “1” represents ON (up).
Protocol 1 2 3
Videoswitch VXP4 and BBV up-the-coax 0 0 0
Videoswitch VXP4 only 1 0 0
PelcoP 0 1 0
PelcoD 1 1 0
Vista 0 0 1
spare 1 0 1
spare 0 1 1
spare 1 1 1
If coax telemetry is not being used, a protocol other than the first one should be selected to
minimise the possibility of spurious commands being received.
1.2.4 Setting the baud rate
Set sections 4 and 5 of the 6-way switch (B) as per the table below to select the
required baud rate. “0” represents OFF (down) and “1” represents ON (up).
The default setting is 9600 baud (both switches OFF)
PelcoD normally uses 2400 baud
PelcoP normally uses 4800 baud
Baud rate 4 5
9600 0 0
2400 1 0
4800 0 1
19200 1 1