owner's manaul HIGH DEFINITION PLASMA DISPLAYS VP-6500VHD, VP-6500VHDa

Installation
20 Vidikron PlasmaView Owner’s Operating Manual
PRE
L
IMINAR
Y
Digital Video Connection: The PlasmaView has a DVI input, labeled DVI-D IN (SLOT 2).
Connect the HDMI output from the VHD Controller to this input, using a DVI-to-HDMI cable
or a DVI cable with a DVI-to-HDMI adapter.
RS-232 Connection: Connect the RS-232 output from the VHD Controller to the SERIAL
input on the PlasmaView. Use a standard, modular telephone cable with RJ11 plugs at both
ends. On the PlasmaView end, use the provided RJ11-to-DB9 adapter. This adapter is wired as
shown in
Figure 3-4.
Figure 3-4. RS-232 Connection from the VHD Controller to the PlasmaView
3
4
2, 5
XMT DATA
RCV DATA
REQUEST TO SEND
SIG GND
3
2
8
7
5
RCV DATA
XMT DATA
CLEAR TO SEND
NO CONNECTION
1, 6
1, 9
SIG GND
To/From
VHD
Controller
PlasmaView
RJ-11 Male
DB-9 Female
1 5
6 9
SERIAL