IM-PP 724607 0320 ProPress
Tube Diameter (inches) Insertion Depth (inches)
1
11
/
16
3 1
15
/
16
4 2⅜
Table 21: Minimum insertion depths ProPress 2½" to 4" 󶈵ttings
Measure insertion depth (see table below).
Mark the proper insertion depth on the outside of the tube.
Improper insertion depth
Improper insertion depth may result in an improper seal.
Be sure to mark the correct insertion depth on the tube
before pressing the 󶈵tting.
Tube
Diameter
(inches)
Minimum
Insertion
Depth (inches)
Minimum
Insertion
Depth (mm)
Maximum
Insertion
Depth (inches)
Maximum
Insertion
Depth (mm)
1
11
/
16
43 2⅝ 67
3 1
15
/
16
50 2
15
/
16
75
4 2⅜ 60 3
7
/
16
87
Table 22: Insertion depths for ProPress 2½" to 4" no-stop couplings
No-stop couplings and extended no-stop couplings are often used to
conduct repairs. Without a stop, these couplings can slide completely
onto a tube and allow a connection to be made in tighter spaces. Unlike
󶈵ttings with an integrated stop that have a minimum insertion depth, no-
stop couplings have minimum and maximum allowable insertion depths.
Both the minimum and the maximum insertion depths must be marked
with a line connecting the two marks.
While turning slightly, slide 󶈵tting onto the tube to marked insertion
depth.
Note: End of tube must contact stop.