Operating instructions

18
Filling the heating system
!
Please note
Unsuitable fill water increases the level of deposits and corrosion and may
lead to boiler damage.
Thoroughly flush the entire heating system prior to filling it with water.
Only use fill water of potable quality.
Soften fill water harder than 300 ppm.
An antifreeze additive suitable for heating systems can be mixed with the
fill water.
1. Close the gas shut-off valve.
2. Switch ON the power.
rr
3. Turn rotary selector "rt" anticlock-
wise for less than 2 s and then clock-
wise back to the control range on the
right.
Filling function is enabled. This func-
tion will end automatically after
20 min or after ON/OFF switch has
been turned OFF.
Commissioning, inspection, maintenance
Further details regarding the individual steps
5366 836 GB