Operation Manual

59
Replacing the lamp
To prepare a new lamp, contact your dealer and tell the lamp type number.
Type number:
Type number:
WARNING
Hg - Lamp contains mercury. Manage in accordance with local disposal
laws. See www.lamprecycle.org
To reduce the risk of electrical shock, always turn the projector off and disconnect the
power cord before changing the lamp.
To reduce the risk of severe burns, allow the projector to cool for at least 45 minutes
before replacing the lamp.
To reduce the risk of injuries to fingers and damage to internal components, use caution
when removing lamp glass that has shattered into sharp pieces. Before replacing the
lamp, clean the lamp compartment and dispose of cleaning materials. Be careful of sharp
edges in the lamp compartment. Wash hands after lamp replacement.
Only ViewSonic certified lamps are tested with this projector. Use of other lamps may
cause electrical shock and fire.
1. Turn the power off and disconnect the
projector from the wall socket. If the
lamp is hot, avoid burns by waiting for
approximately 45 minutes until the
lamp has cooled.
2. Loosen the screws that secure the lamp
cover on the both sides of the projector
until the lamp cover loosens.
3. Remove the lamp cover from the
projector.
WARNING
Do not turn the power on with the lamp
cover removed.
Do not insert your fingers between the
lamp and the projector. The sharp edges
inside the projector may cause injuries.
4. Remove and dispose of the lamp
protection film.
1
2
Type number:
RLC-070
ņ
PJD5226w/PJD6223/PJD6353/PJD6353s/PJD6653w/PJD6653ws
RLC-077
ņ
PJD5126/PJD5226
Ň
RLC-071
ņ
PJD6253/PJD6383/PJD6383s/PJD6553w/PJD6683w/PJD6683ws
Ň
Ň