Planning Your Viking Outdoor Kitchen
COMMON INSTALLATIONS
For actual assembly of individual cabinets, please refer to Viking installation instructions
IN GENERAL
The cabinets have been designed to be easily installed by contractor or consumer. The cabinets are designed
completely of stainless steel and provide a rich, contemporary look that complements Viking outdoor appliances.
The cabinets are 34-1/2” high where the toe kick area is 4-1/2”. Locally supplied countertops must be mounted
on top. The leveling legs on each cabinet alloW. for adjustments on uneven surfaces. The leveling legs alloW. for a
minimum adjustment of 34-1/4” and a maximum of 36”. Typically, the rst cabinet is placed at the highest point and
the other cabinets are leveled from there. To gain the most exibility from the kitchen design, separate all appliances
by at least one base cabinet or with available 4”W. or 8”W. llers (VFLR4/VFLR8). Remember to account for the 8”
minimum the rotisserie motor requires for installation when placing cabinets next to a grill base. All cabinets are 30”
deep.
The cabinets can be installed against a house, a masonry, a stucco half-wall or freestanding in an island conguration.
A stainless side panel (VSP30) is available to nish ends where a wall doesn’t exist. Each cabinet is leveled using the
attached leveling legs and then together. Choose a countertop material of 1-1/4” (like granite, quartz, etc.) or more
(other stone, tile, etc.). If the countertop is greater than 1-1/4” thick, you should use shims (not included) to install the
appliance (grill, side burner, wok) ush to the countertop. After the countertop is installed the appliances are placed
in them and the kitchen is complete.
Note: The full weight of the appliance must be set on the solid bottom support, including shims if necessary, and not supported by the countertop side trim.
AGAINST A NON-COMBUSTIBLE SURFACE
When installing a run of cabinets that includes a grill base against a non-combustible surface, the back of the
cabinets should be at least 3” from the wall to insure meeting the grill specications. When this is the case, a 4”W.
back panel (VBPFLR4) along with a 30” Side Panel (VSP30) can be used to nish the end of the cabinet run. The
VBPFLR4 is screwed into the back of the cabinet that ends the run and matches up against the VSP30.
EXAMPLE:
If any of the undercounter refrigeration products are installed in the cabinet run, a VURO3200 should be
installed to alloW. for solid installation of the side panel and to make a strong base on which the countertop
will sit. If the refrigeration falls in the end of a run a, 30”W. side panel (VSP30) should be used. If used in
conjunction with a Viking outdoor grill, a VBPFLR4 should be used along with the VSP30 to insure meeting
grill specications.
VQBO4121
NON-COMBUSTIBLE
SURFACE
VSP30
VSP30
VBPFLR4 (stainless facing out)
24"W. OUTDOOR REFRIGERATION SLIDES IN
VURO3200 VBO1811
VBPFLR4 (stainless facing out)
VBO1830
= COUNTERTOP
TOP VIEW