Installation guide

IMPORTANT
5
Please Read and FollowRefrigerator Safety
4
A
GFI shall be used if required by NFPA-
70 (National Electric Code),
federal/state/local laws, or local
ordinances.
The required use of a GFI is normally
related to the location of a receptacle with
respect to any significant sources of water
or moisture.
Viking Range Corporation will NOT
warranty any problems resulting from GFI
outlets which are not installed properly or
do not meet the requirements below.
If the use of a GFI is required, it should be:
Of the receptacle type (breaker type or
portable type NOT recommended)
Used with permanent wiring only
(temporary or portable wiring NOT
recommended)
On a dedicated circuit (no other
receptacles, switches or loads in the
circuit)
Connected to a standard breaker of
appropriate size (GFI breaker of the same
size NOT recommended)
Rated for Class A (5 mA +/- 1 mA trip
current) as per UL 943 standard)
In good condition and free from any
loose-fitting gaskets (if applicable in
outdoor situations)
Sheltered from moisture (water, steam,
high humidity) as much as reasonably
possible