Installation 3 Series Hoods RVCH330 RVCH330
Table of Contents Warnings & Important Information_______________________________________________________________________________ 3 RVCH Classic Chimney Wall Hoods w/Standard Ventilator Dimensions & Specifications ________________________________________________________________________ 5 Clearance Dimensions _____________________________________________________________________________ 6 Interior Ventilator Dimensions ______________________________________________________________________ 7 Planning Informati
IMPORTANT– Please Read and Follow! NOTE: If installing hood with warming shelf panel, install warming shelf panel first. WARNING TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING 1. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including firerated construction. 2.
IMPORTANT– Please Read and Follow! WARNING WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGETOP GREASE FIRE, OBSERVE THE FOLLOWING. (Based on “Kitchen Firesafety Tips,” published by NFPA.) TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS Range hoods must be installed with the ventilators that are specified on their carton indicating suitability with this model. Other ventilators cannot be substituted. 1.
Dimensions & Specifications (RVCH Classic Chimney Wall Hoods w/Standard Ventilator) ” 12 cm) 0.5 (3 1 (40 6” .6 cm ) (5. 2” 1c m (3018” .5 c to m) ) (7630” .2 cm ) 1 (30 2” .5 cm ) A ” 24 cm) A (Hood width) 30”W. 29-7/8” (75.9 cm) 36”W. 35-7/8” (91.1 cm) .0 (61 NOTE: Duct cover included.
Clearance Dimensions (RVCH Classic Chimney Wall Hoods w/Standard Ventilator) 66 30 (16 ”m 7.6 in. c 69 to m) (17 ”ma 5.3 x. cm ) (76”mi .2 n. c 33 to m) ” (83 ma .8 x. cm ) ” 36 cm) .
Interior Ventilator Dimensions (RVCH Classic Chimney Wall Hoods w/Standard Ventilator) Top view A 16” (40.6 cm) A 30”W. 14-15/16” (37.9 cm) 36”W. 17-15/16” (45.6 cm) 4” (10.2 cm) 9-3/4” (24.8 cm) 120 V 7” (17.8 cm) dia.
Planning Information Plan where the duct work will be located. Install proper-sized duct work, roof, or wall cap for the type of blower you are using. Adjust your measurements for various heights of ceilings, soffits, cabinets, or ranges/rangetops. Roof cap 7” round duct 300 or 600 CFM single blower interior-power typical ductwork Duct cover or soffit Proper installation of ducting is extremely important to ensure maximum performance from any ventilation product. • All CFMs are based on tests at 0.
Installation (RVCH Classic Chimney Wall Hoods w/Standard Ventilator) 1 2 Attach transition to damper. Seal with aluminum tape. Check damper for unrestricted movement, adjust if necessary. WARNING 3 TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING • Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.
6 5/16” nut driver 5/16” nut driver CAUTION: If not using a duct cover, using screws provided make sure top mounting screws are secured into soffit or cabinet frame. Use additional mounting screws, if necessary. CAUTION: Secure vent hood to wall using screws provided. Use additional mounting screws and wall anchors, if necessary. 7 8 BARE OR GREEN 1 1 GREEN BLACK 2 WHITE BLACK WHITE Connect black to black, white to white, and the green/bare wire under the green screw.
3 1 2 Slide filter front over front lip. Push filter rear up, then slide back over rear lip. Duct Cover (RVCH Classic Chimney Wall Hoods w/Standard Ventilator) 1 2 Measure distance from ceiling to canopy. Tape to avoid scratching. 3 4 2 Place duct cover top inside duct cover base and lower until desired height is found. Mark height. Use the retaining nuts and bolts to fasten in place from the inside and remove tape.
Installation (RVCH Classic Chimney Wall Hoods w/Recirculating Kit) NOTE: If installing a duct cover with a recirculationg kit, the duct cover must be attached to the recirculating kit before installing on the hood. 1 2 2 Remove damper and discard with transition. Turn recirculating unit upside down. Place vent hood upside down on recirculating unit. 4 3 Attach with screws. Attach with screws and lock washers provided.
WARNING 5 TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING • Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer. • Before servicing or cleaning unit, switch power off at service panel and lock service panel to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
11 10 1 2 3 Assemble brackets to mesh filters and insert charcoal filters. Slide filter front over front lip. Push filter rear up, then slide back over rear lip. 13 12 1 3 3 1 2 2 Slide filter front over front lip. Push filter rear up, then slide back over rear lip. Slide spacer front over front lip. Push spacer rear up, then slide back over rear lip.
Service & Registration If service is required, call your authorized service agency. Have the following information readily available. • Model number • Serial number • Date purchased • Name of dealer from whom purchased Clearly describe the problem that you are having.
Viking Range, LLC 111 Front Street Greenwood, Mississippi 38930 USA (662) 455-1200 For product information, call 1-888-845-4641 or visit our website at vikingrange.