Installation Instructions

Clearance Dimensions (Wood/Composite Overlay)
9
The bottom of a standard hood should be
30” (76.2 cm) min. to 36” (91.4 cm) max.
above the countertop. This would
typically result in the bottom of the hood
being 66” (167.6 cm) to 72” (182.9 cm)
above the floor.
Refer to the range hood
installation instructions for additional
information.
These dimensions provide for
safe and efficient operation of the hood.
66”min.
(167.6 cm)
to
72”max.
(182.9 cm)
66”min.
(167.6 cm)
to
72”max.
(182.9 cm)
24”
(61.0 cm)
or
27”
(38.6 cm)
30”
(76.2 cm)
6”
(15.2 cm)
Wood/Composite
Overlay
Wood/Composite
Overlay
30”min.
(76.2 cm)
to
36”max.
(91.4 cm)
0”
(
0 cm)
30”min.
(76.2 cm)
to
36”max.
(91.4 cm)
Wall Installation
Island Installation
Note:
Minimum clearance for back
wall is 0” with backguard or high-
shelf.
Note:
Clearances from non-combustible materials
are not part of the ANSI Z21.1 scope and not
certified by CSA. Clearances to non-combustible
materials must be approved by the authority
having jurisdiction.
Note:
This range ships with an island
trim. There must be a minimum of 6”
(15.2 cm) clearance from rear of
range to a
combustible
wall or 0”
clearance to a
non-combustible
wall.