Brochure

33
Access doors
Description
Overall Width
(including notches)
AD52820 AD51620
28 1/4" (71.8 cm) minimum
30 1/4" (76.8 cm) maximum
DOUBLE AND SINGLE ACCESS DOORS
16 1/4" (41.3 cm) minimum
18 1/4" (46.4 cm) maximum
Overall Height
(opening only)
20 1/4" (51.4 cm) minimum
20 1/2" (52.1 cm) maximum
36", 48", AND 60" WIDE WALL HOODS
18" HIGH WALL HOOD CANOPY – 27" DEEP
Models
Number
of Lights
Number
of Filters
Interior-Power Exterior-Power
Recommended Ventilator Kits
Interior Exterior
Recommended Duct Size
Interior Exterior
Maximum Amps
An interior- or exterior-power ventilator kit must be purchased for installation with all hoods.
VWHO3678 - 36"W
VINV1200
DEV1200/DIL1200/DEV1500
2 2 10" 8.7 6.1/6.810"/10"
VWHO4878 - 48"W
VINV1200
DEV1200/DIL1200/DEV1500
3 3 10" 11.5 8.8/9.510"
VWHO6078 - 60"W
VINV1200
DEV1200/DIL1200/DEV1500
4 4 10" 11.5 8.8/9.510"
DEV1200
Approximate CFM
1
Recommended Duct Size
Maximum Duct Run
2
Maximum Amps
Description
VENTILATOR KITS
Interior Ventilators Exterior Ventilators
DIL1200
VINV1200
1,200 1,200
50 ft. (15.2 m) 50 ft. (15.2 m) 50 ft. (15.2 m)
1,200
SEE HOOD SPECIFICATIONS
SEE HOOD SPECIFICATIONS
Please note: Maximum amp rating for hoods includes recommended ventilator kit rating; all products must be hard wired with 2-wire ground. All ventilator kits use 120VAC/60Hz.
Proper installation is extremely important to ensure maximum performance from any ventilation product.
1. All CFMs stated based on tests with .1 static pressure; without applying static pressure (some brands consciously do not), CFM could be greatly overstated.
2. Duct run length is for general reference only; for longer duct runs, increase duct size and contact a qualified and trained installer.
•Straightrunsandgradualturnsarebest;forexample,each90-degreeelbowisequalto5-10feet(1.52-3.05m)ofstraightrun.
•Neveruseflexibleduct;itcreatesbackpressure/airturbulenceandgreatlyreducesperformance.
•Properperformanceisdependentuponproperducting;makesurethataqualifiedandtrainedinstallerisused.
•Checkwithaqualifiedandtrainedinstallerorlocalcodesformakeupairrequirements,ifany.
In-Line Ventilator Kits
DEV1500
1,500
75 ft. (22.8 m)
Outdoor hoods
Ventilator kits