Installation Guide

11
2
1
1
Remove access door.
Electrical Connection (3-wire)
3
2
1
2
Remove supply cord strain relief
bracket and three supply cord mounting screws
on terminal block.
WARNING
Electrical shock hazard.
To avoid risk or electrical shock,
personal injury or death; grounding
product to the frame of the unit may
or may not be permitted through your local
codes. If ground to the frame is not permitted
then a 4 conductor power cord must be used.
WARNING
Electrical shock hazard.
To avoid risk of electrical shock,
personal injury or death; verify your
appliance has been properly
grounded in accordance with local codes or in
absence of codes, with the National Electrical
Code (NEC). ANSI/NFPA 70-latest edition.
3
Feed supply cord up through hole in
bottom of range back.
Note: If you have a 4-wire connection, see following section for
4-wire connection instructions.
See Electrical Requirements information.
Where local codes do not permit grounding through neutral, use a 4-wire power supply cord. The cord or
conduit must be secured to the range with the strain relief bracket.
The electrical connection is made at the terminal block, which is located behind the access door on the back
of the range.
1
2
4
1
1
3
5
1
2
6
Attach line #1 (black) and line #2 (red)
leads to outside terminal. Attach neutral wire
(white) to center terminal on the terminal
block.
Push supply cord toward terminal
block to relieve strain, reattach supply cord
strain relief bracket over supply cord.
Reattach access door.