Technical data

4. SYSTEM PROGRAMMING WITH PC SOFTWARE
To use the monitoring receiver with monitoring PC connect the mini USB port of receiver
to the USB port of the monitoring PC. Driver installation is automatic (from Windows 7).
After this the appropriate monitoring software settings should be done (it means usually
the serial port and baud rate settings).
The process is the following in AlarmSyS monitoring software:
Start Alarm Start software → Start Alarm Setup and log in (ID: 1, Password: 1) Setup
menu → Hardware Setup → Digital Receiver #1.
In pop-up window basically only Receive and process incoming messages option
should be enabled, then set the proper COM port (checking in Windows OS: Control
Panel / Hardware / Device Manager) and Baud Rate to 57600, then apply changes.
After this receiver events are displayed on monitoring software screen.
Note: To connect IP2 card to monitoring software set Baud Rate value to 57600 in
monitoring software settings.
6