Installation guide

18
© 2011 Directed Electronics. All rights reserved.
1. Aux/Trunk Icon Type: sets the name to be displayed in the Text Field when the Aux/Trunk output is acti-
vated/de-activated
2. Aux 1 Timed Output: sets the output duration in 1 second intervals up to 90 seconds for Aux 1
3. Aux 1 Icon Type: sets the name to be displayed in the Text Field when the Aux 1 output is activated/
de-activated
4. Aux 2 Timed Output: sets the Aux 2 “Timed” output in 1 second intervals up to 90 seconds
5. Aux 2 Icon Type: sets the name to be displayed in the Text Field when the Aux 2 output is activated/
de-activated
6. Aux 3 Timed Output: sets the Aux 3 “Timed” output in 1 second intervals up to 90 seconds
7. Aux 3 Icon Type: sets the name to be displayed in the Text Field when the Aux 3 output is activated/
de-activated
8. Aux 4 Timed Output: sets the Aux 4 “Timed” output in 1 second intervals up to 90 seconds
9. Diesel Start Delay Timer: sets the delay before engine crank in 1 second intervals up to 90 seconds for
diesel engine vehicles
10. Timer Mode Runtime: sets the duration of runtime when the engine is started by the Timer Mode and Smart
Start features
11. Timer mode Starts: sets the number of times the engine will be started by the Timer Mode and Smart Start
features
12. Timer mode Intervals: sets the number of hours between engine starts by the Timer Mode and Smart Start
features
13. Smart Start Low Temperature: sets the low temperature threshold required for Smart Start to start the
engine
14. Smart Start High Temperature: sets the high temperature threshold required for Smart Start to start the
engine
15. Smart Start Low battery (Volts): sets the low battery level threshold required for Smart Start to start the
engine
16. Starter Release Fine Tune: adds or subtracts crank time in Tachometer mode in order to overcome engine
types that short crank or over-crank on the first start attempt
17. Feature Programming: locks and unlocks the user’s ability to enter the feature menus and manually
change the main unit programming using the Control Center
18. Transmitter Programming: locks and unlocks the user’s ability to enter the remote control/Reset menu and
manually change any functions using the Control Center
19. Remote Start Runtime: sets the duration of runtime when the engine is started by remote command
20. VirtualTach Fine tune: adds or subtracts crank time in VirtualTach mode in order to overcome engine types
that short crank or over-crank on the first start attempt