Installation guide

6
© 2011 Directed Electronics. All rights reserved.
Wiring Connections
Main Harness (H1), 6-pin connector
H1/1
RED (+)12VDC CONSTANT INPUT
H1/2
BLACK (-) CHASSIS GROUND
H1/3
BROWN (-) 200mA HORN HONK OUTPUT
H1/4
WHITE/BROWN LIGHT FLASH ISOLATION WIRE - PIN 87a light flash relay
H1/5
WHITE PIN 30 of LIGHT FLASH RELAY
H1/6
ORANGE 500 mA GROUND WHEN ARMED OUTPUT
Auxiliary/Shutdown Harness (H2), 24-pin connector
H2/1
PNK/WHITE (-) 200mA FLEX RELAY CONTROL OUTPUT
H2/2
BLACK/WHITE (-) NEUTRAL SAFETY INPUT
H2/3
BLUE/WHITE (-) 200mA 2ND STATUS /REAR DEFOGGER OUTPUT
H2/4
GREEN/BLACK (-) 200mA FACTORY ALARM DISARM OUTPUT
H2/5
RED/WHITE (-) 200mA TRUNK RELEASE OUTPUT
H2/6
GREEN (-) DOOR INPUT*
H2/7
BLACK/YELLOW (-) 200mA DOME LIGHT OUTPUT
H2/8
EMPTY ------------------------------------
H2/9
DARK BLUE (-) 200mA STATUS OUTPUT
H2/10
PINK (-) 200mA IGNITION 1 OUTPUT
H2/11
WHITE/BLACK (-) 200mA AUX 3 OUTPUT
H2/12
VIOLET (+) DOOR INPUT
H2/13
WHITE/VIOLET (-) 200mA AUX 1 OUTPUT
H2/14
VIOLET/BLACK (-) 200mA AUX 2 OUTPUT
H2/15
ORANGE/BLACK (-) 200mA AUX 4 OUTPUT
H2/16
BROWN (+) BRAKE SHUTDOWN INPUT
H2/17
GRAY (-) HOOD PIN INPUT (NC OR NO)
H2/18
VIOLET/YELLOW (-) 200mA STARTER OUTPUT
H2/19 BLUE**
FACTORY HORN INPUT (Use Jumper to set polarity)
H2/20
GRAY/BLACK (-) DIESEL WAIT TO START INPUT
H2/21
WHITE/BLUE ACTIVATION INPUT
H2/22
ORANGE (-) 200mA ACCESSORY OUTPUT
H2/23
VIOLET/WHITE TACHOMETER INPUT
H2/24
GREEN/WHITE (-) 200mA FACTORY ALARM ARM OUTPUT
*The Normally Closed setting will only work if one of the vehicle's doors is connected. If more than one door
is to be monitored, then it is recommended to use the Xpresskit DTIMAZDA or tech tip # 1921 on www.di-
rectechs.com to interface with these types of vehicles.
**This optional input can be connected to the horn circuit (+ or -). When this wire receives input for a minimum of
.5 seconds, the system reports a trigger on the 2-way remote. This is useful on vehicles that have a factory security
system that can be armed/disarmed with the Directed system. This system will not report that a zone has been
triggered when unlocking with the 2-way remote. This feature is not available on the 1-way remote.