User Manual

www.vishay.com For technical questions, contact: diodes-tech@vishay.com
Document Number: 94018
4 Revision: 07-Apr-08
30EPH06PbF
Vishay High Power Products
Hyperfast Rectifier,
30 A FRED Pt
TM
Fig. 5 - Maximum Allowable Case Temperature vs.
Average Forward Current
Fig. 6 - Forward Power Loss Characteristics
Fig. 7 - Typical Reverse Recovery Time vs. dI
F
/dt
Fig. 8 - Typical Stored Charge vs. dI
F
/dt
Note
(1)
Formula used: T
C
= T
J
- (Pd + Pd
REV
) x R
thJC
;
Pd = Forward power loss = I
F(AV)
x V
FM
at (I
F(AV)
/D) (see fig. 6);
Pd
REV
= Inverse power loss = V
R1
x I
R
(1 - D); I
R
at V
R1
= Rated V
R
0 5 10 15 20 25
Allowable Case Temperature (°C)
I
F(AV)
- Average Forward Current (A)
140
160
180
See note (1)
120
DC
100
80
30 35 40 45
Square wave (D = 0.50)
Rated V
R
applied
0 1020304045
Average Power Loss (W)
I
F(AV)
- Average Forward Current (A)
0
10
30
40
50
D = 0.01
D = 0.02
D = 0.05
D = 0.10
D = 0.20
D = 0.50
DC
20
RMS limit
5 152535
60
70
80
90
0
I
F
= 30 A
I
F
= 15 A
10
100 1000
t
rr
(ns)
dI
F
/dt (A/µs)
40
60
80
90
30
50
70
V
R
= 200 V
T
J
= 125 °C
T
J
= 25 °C
0
20
100 1000
Q
rr
(nC)
dI
F
/dt (A/µs)
600
1000
1200
400
800
V
R
= 200 V
T
J
= 125 °C
T
J
= 25 °C
0
200
I
F
= 30 A
I
F