Datasheet

CMA 0204
www.vishay.com
Vishay Beyschlag
Revision: 27-Mar-17
8
Document Number: 28717
For technical questions, contact: melf@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
Note
(1)
The quoted IEC standards are also released as EN standards with the same number and identical contents
4.19 14 (Na) Rapid change of temperature
30 min at LCT;
30 min at UCT;
LCT = -55 °C; UCT = 125 °C
5 cycles ± (0.5 % R + 0.1 )
1000 cycles ± (1.5 % R + 0.1 )
4.13 -
Short time overload;
standard operation mode
U = 2.5 x 2 x U
max.
;
whichever is the less severe;
5 s
± (0.25 % R + 0.1 )
Short time overload;
power operation mode
U = 2.5 x 2 x U
max.
;
whichever is the less severe;
5 s
± (0.5 % R + 0.1 )
4.22 6 (Fc) Vibration
Endurance by sweeping;
10 Hz to 2000 Hz;
no resonance;
amplitude 1.5 mm or
200 m/s
2
; 7.5 h
± (0.25 % R + 0.1)
4.38 -
Electrostatic discharge
(human body model)
IEC 61340-3-1
(1)
;
3 pos. + 3 neg.
(equivalent to MIL-STD-883,
method 3015)
CMA 0204: 6 kV
± (0.5 % R + 0.05 )
4.17 58 (Td) Solderability
Solder bath method;
SnPb40;
non-activated flux;
(215
±3) °C; (3 ± 0.3) s
Good tinning ( 95 % covered);
no visible damage
Solder bath method;
SnAg3Cu0.5 or
SnAg3.5; non-activated flux;
(235
± 3) °C; (2 ±0.2) s
Good tinning ( 95 % covered);
no visible damage
4.18 58 (Td) Resistance to soldering heat
Solder bath method;
(260 ± 5)
C; (10 ± 1) s
± (0.5 % R + 0.1 )
Reflow method 2
(IR / forced gas convection);
(260 ± 5) °C; (10 ± 1) s
± (0.25 % R + 0.1 )
4.29 45 (XA) Component solvent resistance Isopropyl alcohol; 50 °C; method 2 No visible damage
4.30 45 (XA) Solvent resistance of marking
Isopropyl alcohol; 50 C; method 1,
toothbrush
Marking legible;
no visible damage
4.32 21 (Ue
3
) Shear (adhesion) 45 N No visible damage
4.33 21 (Ue
1
) Substrate bending Depth 2 mm, 3 times
No visible damage;
no open circuit in bent position
± (0.25 % R + 0.1)
4.7 - Voltage proof U
RMS
= U
ins
; 60 s No flashover or breakdown
4.35 - Flammability
IEC 60695-11-5
(1)
,
needle flame test;
10
s
No burning after 30 s
TEST PROCEDURES AND REQUIREMENTS
EN
60 115-1
CLAUSE
IEC
60 068-2
(1)
TEST
METHOD
TEST PROCEDURE
REQUIREMENTS
PERMISSIBLE CHANGE (R)
Stability for product types:
CMA 0204 10 to 100 k
P
70
x R
P
70
x R