Datasheet

CMB 0207
www.vishay.com
Vishay Beyschlag
Revision: 11-Feb-16
7
Document Number: 28755
For technical questions, contact: melf@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
TEST PROCEDURES AND REQUIREMENTS
EN
60 115-1
CLAUSE
IEC
60 068-2
(1)
TEST
METHOD
TEST PROCEDURE
REQUIREMENTS
PERMISSIBLE CHANGE (R)
Stability for product types:
CMB 0207 2.2 to 1.5 M
4.5 - Resistance - ± 5 % R; ± 2 % R; ± 1 % R
4.8 - Temperature coefficient
At (20 / -55 / 20) °C
and (20 / 125 / 20) °C
see Temperature Coefficient graph
4.25.1
-
Endurance at 70 °C:
standard operation mode
U = U
max.
;
whichever is the less severe;
1.5 h on; 0.5 h off;
70 °C; 1000 h ± (1 % R + 0.05)
70 C; 8000 h ± (2 % R + 0.05)
-
Endurance at 70 C:
power operation mode
U = U
max.
;
whichever is the less severe;
1.5 h on; 0.5 h off;
70 °C; 1000 h ± (2 % R + 0.05)
70 C; 8000 h ± (4 % R + 0.05)
4.25.3 -
Endurance at upper category
temperature
125 °C; 1000 h ± (2 % R + 0.05)
155 °C; 1000 h ± (4 % R + 0.05)
4.24 78 (Cab) Damp heat, steady state (40 ± 2C; 56 days; (93 ± 3) % RH ± (1 % R + 0.1 )
4.37 67 (Cy)
Damp heat,
steady state,
accelerated
(85 ± 2) °C
(85 ± 5) % RH
U = 100 V
and U = 0.3 x U
max.
;
(the smaller value is valid)
1000 h
± (2 % R + 0.1 )
4.23 Climatic sequence:
4.23.2 2 (Ba) dry heat UCT; 16 h
4.23.3 30 (Db) damp heat, cyclic 55 C; 24 h; 90 % RH; 1 cycle
4.23.4 1 (Aa) cold LCT; 2 h
4.23.5 13 (M) low air pressure 8.5 kPa; 2 h; (25 ± 10) C
4.23.6 30 (Db) damp heat, cyclic 55 C; 24 h; 90 % RH; 5 cycles
4.23.7 - DC load U = U
max.
; 1 min
LCT = -55 C; UCT = 155 °C ± (1 % R + 0.1 )
- 1 (Aa) Cold -55 C; 2 h ± (0.5 % R + 0.1)
4.19 14 (Na) Rapid change of temperature
30 min at LCT;
30 min at UCT;
LCT = -55 °C; UCT = 125 °C
5 cycles ± (0.5 % R + 0.1 )
1000 cycles ± (1.5 % R + 0.1 )
4.13 -
Short time overload;
standard operation mode
U = 2.5 x 2 x U
max.
;
whichever is the less severe;
5 s
± (0.25 % R + 0.1 )
Short time overload;
power operation mode
U = 2.5 x 2 x U
max.
;
whichever is the less severe;
5 s
± (0.5 % R + 0.1 )
4.22 6 (Fc) Vibration
Endurance by sweeping;
10 Hz to 2000 Hz;
no resonance;
amplitude 1.5 mm or
200 m/s
2
; 7.5 h
± (0.25 % R + 0.1)
P
70
x R
P
70
x R
0.3 x P
70
x R
P
70
x R
P
70
x R
P
70
x R