Datasheet

VOT8121AM
www.vishay.com
Vishay Semiconductors
Rev. 1.2, 30-Oct-2018
3
Document Number: 84914
For technical questions, contact: optocoupleranswers@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
Notes
Minimum and maximum values were tested requirements. Typical values are characteristics of the device and are the result of engineering
evaluations. Typical values are for information only and are not part of the testing requirements
(1)
Static dV/dt
Note
Minimum and maximum values were tested requirements. Typical values are characteristics of the device and are the result of engineering
evaluations. Typical values are for information only and are not part of the testing requirements
Note
As per IEC 60747-5-5, § 7.4.3.8.2, this optocoupler is suitable for “safe electrical insulation” only within the safety ratings. Compliance with
the safety ratings shall be ensured by means of protective circuits
ELECTRICAL CHARACTERISTICS (T
amb
= 25 °C, unless otherwise specified)
PARAMETER TEST CONDITION SYMBOL MIN. TYP. MAX. UNIT
INPUT
Forward voltage I
F
= 20 mA V
F
- 1.15 1.5 V
Reverse current V
R
= 6 V I
R
- - 10 μA
OUTPUT
Off-state current V
DRM
= 800 V I
DRM
--0.1μA
On-state voltage I
T
= 100 mA peak V
TM
-1.73 V
Holding current I
H
- 250 - μA
Critical rate of rise of off-state voltage dV/dt
(1)
1000 - - V/μs
COUPLER
Trigger current V
TM
= 3 V I
FT
--10mA
SWITCHING CHARACTERISTICS (T
amb
= 25 °C, unless otherwise specified)
PARAMETER TEST CONDITION SYMBOL MIN. TYP. MAX. UNIT
Turn-on time
V
D
= 6 V to 4 V, R
L
= 100 Ω,
I
F
= rated I
FT
x 1.5
t
on
- 30 100 μs
SAFETY AND INSULATION RATINGS (T
amb
= 25 °C, unless otherwise specified)
PARAMETER TEST CONDITION SYMBOL VALUE UNIT
Climatic classification According to IEC 68 part 1 55 / 115 / 21
Comparative tracking index Insulation group IIIa CTI 175
Maximum rated withstanding isolation voltage According to UL1577, t = 1 min V
ISO
3750 V
RMS
Maximum transient isolation voltage According to DIN EN 60747-5-5 V
IOTM
6000 V
peak
Maximum repetitive peak isolation voltage According to DIN EN 60747-5-5 V
IORM
565 V
peak
Isolation resistance
V
IO
= 500 V, T
amb
= 25 °C R
IO
10
12
Ω
V
IO
= 500 V, T
amb
= 100 °C R
IO
10
11
Ω
Output safety power P
SO
300 mW
Input safety current I
SI
50 mA
Input safety temperature T
S
150 °C
Creepage distance > 5 mm
Clearance distance > 5 mm
Insulation thickness DTI > 0.4 mm