ENVI Series IP Configuration Manual VITEK Lens not included VTC-C770WDR/IP2 High Resolution H.264 IP Network Camera w/WDR VTC-IRH70-650/IP2 Long Range IR High Resolution H.264 IP Network Camera Lens not included VTC-C770DN/IP2 High Resolution H.
ENVI Series IP Configuration Manual ________________________________________________________________________________ Safety Precaution Make sure to turn off the power before installing any ENVI IP2 Series product. Do not install under direct sunlight or in dusty areas. Make sure to use the product within the temperature and humidity ranges that are specified. Do not operate the product in the presence of vibrations or strong magnetic fields.
ENVI Series IP Configuration Manual ________________________________________________________________________________ Table of Content Table of Contents .................................................................................................................................... 3 1. Introduction ......................................................................................................................................... 4 1. About User Manual ...............................................
ENVI Series IP Configuration Manual ________________________________________________________________________________ 1. Introduction 1. About User Manual This user manual provides information on operating and managing the VITEK-ENVI Series IP products. The manual includes instructions of installation, operation, configuration and troubleshooting. 2. Features The ENVI Series IP Cameras are network cameras with remote live monitoring, and control via an IP network such as LAN, ADSL/VDSL, and Wireless LAN.
ENVI Series IP Configuration Manual ________________________________________________________________________________ High Reliability Reliable embedded system System recovery by dual watch-dog functions 3. System Connections ENVI IP2 Series Cameras can be connected through either „1 to 1‟ connection, where one ENVI IP2 camera is connected to one PC client or a decoder system, or „1 to many‟ connections, where one ENVI IP2 Camera is connected to several PCs and decoder systems.
ENVI Series IP Configuration Manual ________________________________________________________________________________ 1: N Connection. Remote Center Site PC or Decoder ENVI CAM PC or Decoder PC or Decoder In this configuration, a site can be monitored from many remote central locations. Although up to 64 PCs or decoders can be connected to the ENVI IP Camera, network bandwidth can limit the maximum connections. .
ENVI Series IP Configuration Manual ________________________________________________________________________________ CMS (Central Monitoring System) Site Remote Center ENVI CAM CMS Site ENVI CAM Remote Center Decoder CMS CMS is a Window-based remote monitoring program in order to monitor or control video, and events in real time from several IP cameras or video servers. Please refer to the CMS User Manual for more detail.
ENVI Series IP Configuration Manual ________________________________________________________________________________ 2. Installation 1. Connecting Network (LAN) Connect a LAN Cable to LAN port of HTP-T13MG. 2. Connecting Serial Ports The RS-485 of the ENVI IP2 Camera can be connected to external equipment such as PT receiver etc. PC client can send PT commands to the external equipment via the serial port.
ENVI Series IP Configuration Manual ________________________________________________________________________________ 3. System Operation 1. Remote Video Monitoring There are two ways to monitor video when the decoder site and the ENVI IP2 Camera are connected. For proper operation, an IP address must be set accordingly. Please refer to ENVI VMS in Chapter 3 or Remote Setting in Chapter 4 for further details.
ENVI Series IP Configuration Manual ________________________________________________________________________________ Video Selection The ENVI IP2 Cameras are capable of dual streaming. Video Selection allows you to choose Primary Video image or Secondary Video image. Video Image is displayed according to the resolution set on video configuration. When dual streaming is not activated and secondary mode is selected, video cannot be displayed.
ENVI Series IP Configuration Manual ________________________________________________________________________________ Sensor Input ENVI IP2 Series cameras support one sensor input. Status of the sensor is displayed in real time. When the sensor connected to the ENVI IP2 camera is working, the light turns red. Alarm Output ENVI IP2 Series cameras support one Alarm output. A number icon indicates status of the alarm device. To operate the alarm device, press the number icon.
ENVI Series IP Configuration Manual ________________________________________________________________________________ 4. Remote Configuration Using web browser Remote setting is available by using a web browser. Enter the IP address of the ENVI IP2 Camera and then a live view screen appears as below. Press the Setup button located in the upper right area of the monitoring screen to go to the server setup. For Remote Setting, user should be authorized personnel, higher than manager level.
ENVI Series IP Configuration Manual ________________________________________________________________________________ 1.
ENVI Series IP Configuration Manual ________________________________________________________________________________ General System ID The set System ID is displayed by video image on a Web browser. The System ID is also transferred to remote software, such as CMS, and displayed on it.
ENVI Series IP Configuration Manual ________________________________________________________________________________ Time Start Time Displays latest system boot date and time. Current Time Displays current date & time: To update the date and time, enter a new date and time and press Set Current Time. Time Format Change the time format. Selectable time formats are as shown: - YYYY/MM/DD hh:mm:ss (Ex. 2010- 4-11 18:18:42) - DD/MM/YYYY hh:mm:ss (Ex.11- 4-2010 18:18:42) - MM/DD/YYYY hh:mm:ss (Ex.
ENVI Series IP Configuration Manual ________________________________________________________________________________ The Network Time Protocol (NTP) is a protocol for synchronizing the clocks of computer systems over packet-switched, variable-latency data networks. It is designed particularly to resist the effects of variable latency by using a jitter buffer. Reboot Reboot Server Pressing the Reboot Server button will cause the system to reboot.
ENVI Series IP Configuration Manual ________________________________________________________________________________ 2.
ENVI Series IP Configuration Manual ________________________________________________________________________________ Encode Input Format Choose video type to be used between composite NTSC or composite. Resolution Selectable video compression resolution: NTSC: 720X480, 720x240, 352X480, 352X240, 176X120 PAL: 720X576, 720X288, 352X576, 352X288, 176X144 Frame rate Determine the maximum number of frames of video images to compress.
ENVI Series IP Configuration Manual ________________________________________________________________________________ HIP is the primary profile for broadcast and disc storage applications, particularly for highdefinition television applications (for example, this is the profile adopted by the Blu-ray Disc storage format and the DVB HDTV broadcast service). - Baseline Profile (BP) BP is primarily for low-cost applications that require additional data loss robustness.
ENVI Series IP Configuration Manual ________________________________________________________________________________ Sensitivity Sensitivity is the condition to trigger an event of motion detection. The value determines the sensitivity of the motion detection within a block: the smaller, the more sensitive. It is selectable from 0 to 10. Information Display System ID and/or server time can be display over the video window in Internet Explorer.
ENVI Series IP Configuration Manual ________________________________________________________________________________ 3.
ENVI Series IP Configuration Manual ________________________________________________________________________________ Local IP mode Two IP modes are supported. Depending on the selected mode, further configuration items come as follows: IP Mode Selection Local IP Fixed IP Fixed IP address Local Gateway IP address Gateway Local Subnet DHCP Description Subnet mask N/A Find IP address information from ISP provider or network manager.
ENVI Series IP Configuration Manual ________________________________________________________________________________ HTTP Port HTTP port used for web-based connection RTSP Port Enter RTSP port, which is used for RTSP-based connection. The default RTSP port is 554.
ENVI Series IP Configuration Manual ________________________________________________________________________________ SNMP SNMP (Simple Network Management Protocol) is compatible with both SNMPv1 and SNMPvec. Settings for using SNMP (Simple Network Management Protocol) are as follows: SNMP Listen Port: The port is for connecting external devices when system operates as a SNMP client. SNMP is not used by setting 0 value. SNMP Trap Destination IP: Set the SNMP Trap Destination IP.
ENVI Series IP Configuration Manual ________________________________________________________________________________ Bitrate control When there is more than one client connected to the ENVI IP2 camera, some of them do not have enough bandwidth to receive encoded stream completely due to bandwidth difference among the clients. In this case, it is possible to select the way to stream video to clients as follows: - Frame Drop Mode: Encoding will be adjusted to the client with the highest bandwidth.
ENVI Series IP Configuration Manual ________________________________________________________________________________ 4.
ENVI Series IP Configuration Manual ________________________________________________________________________________ Serial Port Configuration There is one serial port, RS-485, for each ENVI Series IP2 Camera. The serial ports can be configured as follows: Each serial port configuration must be the same as the connecting device.
ENVI Series IP Configuration Manual ________________________________________________________________________________ 5.
ENVI Series IP Configuration Manual ________________________________________________________________________________ The ENVI IP2 Camera has one sensor port and one alarm port. When a decoder system, instead of a PC client, is connected to an ENVI IP2 Camera, one system becomes a Local system and the other a Remote system. (Generally a system that is being used by the user is called as Local system). Then, actions for events can be configured for events from the remote system as well as for local system.
ENVI Series IP Configuration Manual ________________________________________________________________________________ Alarm and Beep activation duration Set the duration of alarm or beep activation in case of an event. If it is set to continuous, it will be in an active state until an operator resets it manually. E-mail Notification Specify where the event information is to be sent when E-mail is selected as an event action. Server Address: Enter an address of mail (SMTP) server.
ENVI Series IP Configuration Manual ________________________________________________________________________________ 6. Preset Configuration Enter Nam Move PTZ Camera to normal view Press Set Button Save This function is only available when a PTZ receiver is used with ENVI IP2 Camera. Configure up to 15 preset positions. Preset function is not available on some PTZ receivers. Make sure the PTZ receiver supports preset.
ENVI Series IP Configuration Manual ________________________________________________________________________________ 7.
ENVI Series IP Configuration Manual ________________________________________________________________________________ Recording to SD card A/V data can be recorded to an SD card. An SD card of at least 1GB in size is recommended. Either EXT3 or FAT32 file system can be used. Linux PC can read any of these file systems. On the other hand, only memory device with FAT32 file system can be read in Windows PC. * Recording feature has been added from 102D_001 firmware version.
ENVI Series IP Configuration Manual ________________________________________________________________________________ Disk status Description Disk error detected Error. No disk Disk is not connected to the system. Searching Disk information Checking the status of disk. Refresh the page and wait until the status is changed. Mounting and Performing recovery process when disk damage is found. It takes seconds or minutes to recover. Recovering Disk...
ENVI Series IP Configuration Manual ________________________________________________________________________________ General Use record - On: Recording function will be used when “On” is selected. - Off: Recording function will not be used when “Off” is selected Select Video: Select video streaming between primary video and secondary video. Overwrite: When Overwrite is on, an action can be configured when the disk is full.
ENVI Series IP Configuration Manual ________________________________________________________________________________ Checking status of recording Recording status can be shown on the main view page. Recording status can be also shown in the ENVI VMS. When data is being recorded, Record column displays ON sign.
ENVI Series IP Configuration Manual ________________________________________________________________________________ Search and Playback Recorded File Recorded video data can be saved in AVI format on the disk. In general, one AVI file is created for each event in case of event-based recording. However, it is possible that recorded data of events happening continuously can be merged to a single AVI file depending on pre/post event time setting.
ENVI Series IP Configuration Manual ________________________________________________________________________________ Selecting an AVI file will show a dialog for opening or saving the file . By pressing the Save button, the file will be stored in the PC. The AVI file can be played with Windows Media Player. If you press Open in the dialog, the file will be downloaded and played automatically with Media Player.
ENVI Series IP Configuration Manual ________________________________________________________________________________ If you want to delete recorded files, select the files by checking the box in front of each file and press the Delete button. It is possible to delete multiple files at once. Formatting Disk ENVI VMS is used to format a disk that is connected to the system. After connecting ENVI VMS to a system, choose Disk Manage on the Tools menu.
ENVI Series IP Configuration Manual ________________________________________________________________________________ ENVI While formatting a disk, the progress will update and show on the Disk Status. The system may be rebooted depending on the situation. When USB Disk available is displayed, the formatting has completed successfully. Once formatting is started, it cannot cancel. Even if you close Disk Manage dialog, formatting is continued.
ENVI Series IP Configuration Manual ________________________________________________________________________________ 8. User Configuration User List A user can be registered and the privilege level of a user can be specified. User configuration is allowed only to admin user. A max of 16 users can be registered and each user can have one of four privileges.
ENVI Series IP Configuration Manual ________________________________________________________________________________ Add User The page for adding a user appears when the Add button is pushed. User ID and password need to be entered and the privilege level needs to be selected. User ID and password consists of an alphanumeric string of max 15 characters. Delete User A user is deleted by pressing the Delete button.
ENVI Series IP Configuration Manual ________________________________________________________________________________ Modify Privilege Level Pressing Modify Privilege button after selecting a user allows you to change the privilege. You may not change the privilege level of the admin user. Login Policy Authentication Type For user login, access algorithm can be selected: Basic or Digest HTTP authentication based on RFC 2617 (HTTP Authentication: Basic and Digest Access Authentication) is supported.
VITEK LIMITED PRODUCT WARRANTY VITEK products carry a three (3) year limited warranty. VITEK warrants to the purchaser that products manufactured by VITEK are free of any rightful claim of infringement or the like, and when used in the manner intended, will be free of defects in materials and workmanship for a period of three (3) years, or as otherwise stated above, from the date of purchase by the end user.
28492 CONSTELLATION ROAD VALENCIA, CA 91355 WWW.VITEKCCTV.