User manual

ENVI Series IP Configuration Manual
________________________________________________________________________________
35
General
Use record - On: Recording function will be used when On is selected.
- Off: Recording function will not be used when Off is selected
Select Video: Select video streaming between primary video and secondary video.
Overwrite: When Overwrite is on, an action can be configured when the disk is full. If
Overwrite Off is set, recording stops automatically when there is less than 100MB free space
in the disk. If Overwrite On is set, recording continues by deleting the oldest data first on the
disk, maintaining free space of 300MB for normal operation.
Max File Size: Max File Size option is for limiting the size of an AVI file. If a small file size is set,
small files will be generated yielding a higher number of files. If recording time is set for more
than 10 minutes, a new file will be created even though the previous file size is smaller than the
set max file size.
Event Type
Three recording modes are supported by ENVI IP2 Series Cameras: Full-time, Event, and
Disconnect. In case of Event recording, event types can be selected among several events.
Selected event type is used for configuring the schedule table. Up to 4 event types can be
configured and each event type can be a combination of sensor, video loss and motion event.
Pre-event Time: Specify the duration of recording before an event happens.
Post-event Time: Specify the duration after the event is cleared
Schedule Table
Actual recording mode is determined by the Schedule Table, where recording mode is configured
by day (of a week) and time.
Each recording mode configures the recording operation as follows:
Record off : No recording
Continuous : Records continuously
Disconnect: Data is recorded when the system loses the connection to its client (Decoder,
CMS/NVR) etc. When one of its multiple clients system is disconnected, this doesn‟t happen.
Event Type: Records when an event is configured in Event Type.