12. A/B/C FUNCTION AND CURVE GENERATOR
The A/B/C function determines the duration (0 to 600 seconds) for which the respective voltage
source A/B/C remains active before it moves to the next voltage source.
BeforesettingtheA/B/CfunctionrstentertheΔV/Δtvalue(→chapter11b).
1. Press and hold the MENU (8) button for approx. 3 seconds.
2. Turn the setting controller VOLTAGE (4) until the following display appears:
3. Then press the setting controller VOLTAGE (4) to reach the setting mode.
4. Select the function A, B or C and turn the setting controller CURRENT (5) to set the time
period (0 to 600 seconds).
Example 1:
Pulse waveform with 3 seconds at 10 V and 1 second at 5 V
A (PRESET 1) = 5 V
B (PRESET 2) = 10 V
FUNC A = 1 second
FUNC B = 3 seconds
Δta-b=0
Δtb-a=0
1. To generate the waveform, press the SHIFT (8) button, then the ΔV/Δt (8) button.
2. The waveform will be periodically generated.