User manual

57
The voltage at the remote control connection should not exceed 5 V. The
connections should not be short circuited.
c) Control via controllable resistance (potentiometer)
The power supply can be remote controlled with an external potentiometer (5 kOhm) over the
entire range for voltage and current.
Connect the connection lines to the remote sockets as illustrated.
Voltage setting "V"
Connection 1 at one end of the resistor.
Connection 2 at the middle sliding contact
of the resistor.
Connection 4 at the second end of the
resistor.
Current setting "I":
Connection 1 at the end of the resistor.
Connection 3 at the middle sliding contact
of the resistor.
Connection 4 at the second end of the
resistor.
The connections 1 and 4 should not be short circuited.
d) Output remote control (on/off)
The DC output can be switched on and off via a switch contact. Proceed as follows for the
connection:
1. Connect the connection lines to the remote sockets as illustrated.
2. Connect the 4 and 5 connection to a potential free switch contact.
3. The statusdisplaysC.V.andC.C.ashwhenthe outputis switchedoff.Inaddition the
display (2) indicates the current settings of the output voltage and output current.
4. You can determine the output values with the setting controller for voltage VOLTAGE (4) and
current limitation CURRENT (5) when the output is switched off.