Instructions

Table Of Contents
Digital Storage Oscilloscope 39
1. Run/Stop decode;
2. Return to the previous interface;
3. Save data. Available when the USB memory device is inserted.
4. Decoded data area.
2.7.11 LIN Trigger
LIN triggering can trigger on the rising edge at the Sync Break exit of the LIN
single-wire bus signal (that marks the beginning of the message frame), the Frame ID,
or the Frame ID and Data. A LIN signal message frame is shown below:
1. Press the [Trig Menu] button on the front panel to enter the Trigger system function
menu.
2. Press the Type softkey, then turn the Universal Knob to select LIN and push down
the knob to confirm.
3. Press the Source softkey, turn the Universal Knob to select CH1~CH4 as the
trigger source.
4. Press the Buad Tate softkey, and turn the Universal Knob to set the Baud Rate.
5. Press the Idle Level softkey, and turn the Universal Knob to set the Idle Level.
6. Press the Identifier softkey, and turn the Universal Knob to set the Identifier. The
range is from 0x00 to 0x3f.
7. Press When softkey to set trigger condition.
Interval Field - The oscilloscope triggers when the interval field end.