Instructions

6
.
Technical Specifications
34
6. Technical Specifications
Function
Range
[2]
Resolution
Accuracy: ± (% of reading + LSB)
DC Voltage
50.000 mV
0.001 mV
0.1% + 10
500.00 mV
0.01 mV
0.05% + 5
5.0000 V
0.0001 V
0.05% + 5
50.000 V
0.001 V
0.05% + 5
500.00 V
0.01 V
0.1% + 5
1000.0 V
[3]
0.1 V
0.1% + 10
True RMS
AC Voltage
[4]
500 mV 750 V
20 Hz 45 Hz
1% + 30
45 Hz 65 Hz
0.5% + 30
65 Hz 1 kHz
0.7% + 30
DC Current
500 uA
0.01 uA
0.15% + 20
5000 uA
0.1 uA
0.15% + 10
50 mA
0.001 mA
0.15% + 20
500 mA
0.01 mA
0.15% + 10
5 A
0.0001 A
0.5% + 10
10 A
[5]
0.001 A
0.5% + 10
True RMS
AC Current
[6]
500 uA 500 mA
/
0.5% + 20
5 A 10 A
1.5% + 20
Resistance
[7]
500 Ω
0.01 Ω
0.15% + 10
5
0.0001
0.15% + 5
50
0.001
0.15% + 5
500
0.01
0.15% + 5
5
0.0001
0.3% + 5
50
0.001
1% + 10
Diode
3.0000 V
0.0001 V
1% + 10
Continuity
1000 Ω
0.1 Ω
Adjustable threshold
Frequency
10.000 Hz 60 MHz
[8]
/
± (0.2% + 10)
Capacitance
[9]
50 nF 500 uF
/
2.5% + 10
5 mF 50 mF
/
5% + 10
Temper
ature
K type
-200.0~1360.0
0. 1
°
C
1% + 10
PT100
-200.0~850.0
1
°
C
1% + 5
Display
55,000
Record Interval
15 mS 9999.999 S
Record Length
1,000 points
[1]
Specifications are for 30-minute warm-up, "Low" measurement rate and calibration temperature
18 - 28.
[2] 10% over range on all ranges, except 1,000 V DCV, 750 ACV, 10 A DCI, 10 A ACI, 50 resistance, and
50 mF capacitance.
[3] For each additional volt over ± 500 VDC add 0.02 mV of error.
[4] Specifications are for amplitude of sine wave input > 5% of range. 0.1% errors will be added when the
range of input sine wave is 1% to 5%.