Technical data

8
General instructions
During service operations use the same agent or an
alternative from a different manufacturer.
Make sure that mating surfaces are dry and free from
oil, grease, paint and anti-corrosion agent before ap-
plying sealant or locking fluid. Always follow the man-
ufacturer’s instructions for use regarding temperature
range, curing time and any other instructions for the
product.
Two different basic types of agent are used on the en-
gine and these are:
RTV agent (Room temperature vulcanizing). Used for
gaskets, sealing gasket joints or coating gaskets.
RTV is visible when a part has been disassembled;
old RTV must be removed before resealing the joint.
The following RTV agents are mentioned in the Ser-
vice Manual: Loctite® 574, Volvo Penta P/N 840879-1,
Permatex® No. 3, Volvo Penta P/N 1161099-5, Perma-
tex® Nr 77. Old sealant can be removed using methyl-
ated spirits in all cases.
Anaerobic agents. These agents cure in an absence of
air. They are used when two solid parts, for example
cast components, are installed face-to-face without a
gasket. They are also commonly used to secure
plugs, threads in stud bolts, cocks, oil pressure
switches and so on. The cured material is glass-like
and it is therefore colored to make it visible. Cured
anaerobic agents are extremely resistant to solvents
and the old agent cannot be removed. When reinstall-
ing the part is carefully degreased and then new seal-
ant is applied.
The following anaerobic agents are mentioned in the
Workshop Manual: Loctite® 572 (white), Loctite® 241
(blue).
Note: Loctite® is the registered trademark of Loctite Corparation,
Permatex® the registered trademark of the Permatex Corpora-
tion.