User's Manual

— 3 —
F35628 (10-04)
INTRODUCTION
Procedures in this manual will apply to all
models unless specified. Pictures and
illustrations can be of any model unless the
picture or illustration needs to be model
specific. All models are equipped with 30,000
BTU/HR burners as standard equipment. One
burner is used for every 12 inches of griddle
surface.
All models use an automatic spark igniter to
light the burners.
INSTALLATION
Generally, installations are made by the dealer
or contracted by the dealer or owner. Detailed
installation instructions are included in the
Installation & Operation Manual which is sent
with each unit.
OPERATION
Detailed operation instruction are included in
the Installation and Operation Manual which
is sent with each unit.
CLEANING
Detailed cleaning procedures are included in
the Installation and Operation Manual which
is sent with each unit.
LUBRICATION
No lubrication is required on this equipment.
SPECIFICATIONS
Electrical Data
Model Volts Hertz Phase Amps
924RE 120 60 1 0.5
936RE 120 60 1 0.5
948RE 120 60 1 0.5
960RE 120 60 1 0.5
972RE 120 60 1 0.5
Gas Data
Model Input BTU/HR Manifold Pressure
Natural LP Gas Natural LP Gas
924RE 60,000 60,000 5.0” W.C. 10” W.C.
936RE 90,000 90,000 (1.1 kPa) (2.2 kPa)
948RE 120,000 120,000
960RE 150,000 150,000
972RE 180,000 180,000
TOOLS
Standard
· Hand tools (standard set)
· VOM with AC current tester (any
quality VOM with a sensitivity of at least
20,000 ohms per volt can be used)
· Temperature tester (thermocouple type)
· Manometer
GENERAL