Indoor Fireplace User Manual

Page 719400-3-0406
Mantel Chart (Figure 3)
Figure 3
Clearances (Figure 4)
Clearance from top front edge of fireplace to ceiling is 36"
Clearance from side of fireplace to adjacent sidewall is 6".
Figure 4
Figure 5
Note: When you install your
Fireplace on wall corner
positions, a minimum of 6 inches
clearance must be maintained
from the perpendicular side wall
and the screened opening of the
appliance.
Figure 2
Combustible Material
No greeting cards, stockings or ornamentation of any type should
be placed on or attached to the fireplace. The flow of heat can
ignite combustibles.
Clearance to Combustibles
Back 0" (0 mm)
Side 0" (0 mm)
Floor 0" (0 mm)
Top Stand-off 0" (0 mm)
Top Framing Edge 1" (25mm)
12”
TO
P EDGE OF FIREPLACE
12” (305mm)
10” (254mm)
MANTEL
COMBUSTIBLE TRIM
AND MANTELS
ALLOWED
IN SHADED AREA
1/4”
(6.35mm)
3”
4”
5”
6”
8”
10 3/4”
3/4”
1 ½
2 1
/4”
3”
3 3
/4”
4 ½
6”
8”
1”
2”
SEE MANTLE CHART
FOR
MAXIMUM MANTLE DEPTH
NAILING
FLANGES
GLASS
FRONT
(OPTIONAL)
TO
P FRAMING
LEDGE
FINISHED
WALL
(COMBUSTIBLE)
SEE
MANTLE CHAR
T
FOR MINIMUM HEIGHT
OF
MANTLE ABOVE
UNI
T
2" x 4
" HEADER
STAND
OFF
3" (76 mm) HEIGHT
ABOVE TOP O
F
FIREPLACE
CLEARANCES
LOCATING FIREPLACE