- VULCAN-HART COMPANY GAS BROILER SERVICEMANUALHCB40 ML-052211 GHCB44 ML-052213 GHMCB44 ML-052214 HCB1 ML-052202 HCB2(B) ML-052208 IR1 ML-052200

– 9 –
Oven Bottom Assembly (GHCB40)
WARNING: SHUT OFF THE GAS BEFORE
SERVICING.
WARNING: ALL GAS JOINTS DISTURBED
DURING SERVICING MUST BE CHECKED FOR
LEAKS. CHECK WITH SOAP AND WATER
SOLUTION (BUBBLES). DO NOT USE AN OPEN
FLAME.
1. Remove the lower front panel as outlined in
Covers, Panels and Handles.
2. Open oven door.
3. Remove rack if necessary.
4. Remove the two screws and brass bushings
from the broiler.
5. Loosen the two bolts on the retainer brackets.
6. Remove the oven bottom assembly from the
broiler.
7. Remove the oven bottom baffle from the
broiler.
8. Remove the oven insulation sheet.
9. Remove the oven bottom tray.
10. Reverse the procedure to install.