- Vulcan Electric Tilting Counter Kettle Installation & Operation Manual

— 6 —
ELECTRIC TILTING COUNTER KETTLES
INSTALLING ELECTRIC KETTLE ON
COUNTER
Fig. 3 Mounting Hole Location
1. Position the kettle on the counter or stand
in its final installed location with sufficient
rear clearance (see Table 2 for minimum
required clearance) from the wall to allow
the kettle to tilt completely without
obstruction. Mark the four corner locations
of the kettle base as shown in Fig. 3.
2. Remove the kettle from the counter and
drill four
7
/16" diameter holes according to
the measurements in Fig. 3.
3. Prepare a clean, dry surface according to
package directions on a high grade NSF
listed sealant.
4. Apply a continuous bead of sealant along the
complete outer edges of the kettle base.
5. Position the kettle in place and secure
firmly with supplied hardware.
6. Thoroughly wipe off excess sealant.
INSTALLATING FLOOR MOUNTED K20ETT
1. Position the kettle in its final installed
location to provide drainage directly below
pour path, with sufficient rear clearance
(see Table 2) from the wall to allow the
kettle to tilt completely without obstruction.
2. Level the kettle by making necessary
adjustments using the flanged feet.
3. Mark anchoring hole locations through the
flanged feet.
4. With hole location marked, drill holes to
accommodate
5
/16" studs.
5. Reposition the kettle.
6. Bolt the kettle down and apply a high grade
NSF listed sealant around bolt heads and
flange making contract with floor surface.
Wipe off excess sealant immediately.
ELECTRICAL CONNECTION
Electrical and grounding
connections must comply with the applicable
portions of the National Electrical code and/
or other local electrical codes.
1. Open control box.
2. Connect electric supply to terminal block.
3. See wiring diagram located inside the
control box lid.
ELECTRICAL SPECIFICATIONS
TABLE 3. ELECTRICAL SPECIFICATIONS
Model PH 208V / 240V 308V / 480V
K6ETT 1 7.5 kW-10kW N/A
K12ETT, 1 12 kW-16kW N/A
K20ETT
K6ETT 3 7.5 kW-10kW 7.5 kW
K12ETT, 3 12 kW-16kW 12 kW
K20ETT
Note: K6ETT and K12ETT have external
terminal block. In K20ETT, terminal
block is inside control box.