INSTALLATION & OPERATION MANUAL V SERIES FOOD HOLDING & TRANSPORTATION CABINETS AND BANQUET CARTS MODELS: VB90 VB96 VB150 VBP5I VBP7I VBP13I VBP15I VBP33 VBP77I VBS15 VHA9 VHA18 VHDP5 VHFA9 VHFA18 VHP3 VHP7 VHP8 VHP15 VHP20 ML-126548 ML-126550 ML-126552 ML-138030 ML-126358 ML-126359 ML-126360 ML-138075 ML-126361 ML-138033 ML-138072 ML-138073 ML-138035 ML-138070 ML-138071 ML-126343 ML-126344 ML-126345 ML-126346 ML-126347 For additional information on Vulcan-Hart or to locate an authorized parts and service
V SERIES FOOD HOLDING, TRANSPORT, & BANQUET CARTS F-41140 (09-09) IMPORTANT FOR YOUR SAFETY THIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED TO INSTALL ELECTRICAL EQUIPMENT, WHO SHOULD PERFORM THE INITIAL FIELD STARTUP AND ADJUSTMENTS OF THE EQUIPMENT COVERED BY THIS MANUAL. FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS OR LIQUIDS IN THE VICINITYOF THIS OR ANY OTHER APPLIANCE.
V SERIES FOOD HOLDING, TRANSPORT, & BANQUET CARTS F-41140 (09-09) TABLE OF CONTENTS IMPORTANT FOR YOUR SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
V SERIES FOOD HOLDING, TRANSPORT, & BANQUET CARTS F-41140 (09-09) GENERAL If the cabinet is found to be damaged, save the packaging material and contact the carrier within 15 days of delivery. INTRODUCTION Vulcan-Hart Holding & Transport Cabinets and Banquet Carts are produced with quality workmanship and material. Proper installation, usage, and maintenance of your cabinet will result in many years of satisfactory performance.
V SERIES FOOD HOLDING, TRANSPORT, & BANQUET CARTS CLEANING: The cabinet should be thoroughly cleaned prior to putting into service. F-41140 (09-09) ELECTRICAL REQUIREMENTS ELECTRICAL CODES & STANDARDS: The cabinet must accordance with: Use a mild soap and water solution to clean the interior of the unit. Never use harsh chemicals or abrasive pads to clean the unit. be installed in In the United States of America: 1. State and Local Codes. 2. National Electrical Code, ANSI/ NFPA-70 (latest edition.
V SERIES FOOD HOLDING, TRANSPORT, & BANQUET CARTS F-41140 (09-09) receptacle is not the proper grounding type, contact an electrician. DO NOT REMOVE THE GROUNDING PRONG FROM THIS PLUG. CAUTION: Verify that the power source matches the Serial Data Plate located on the lower back corner of the cabinet and the plug configuration before the connection is made. (Fig.2) (Fig.
V SERIES FOOD HOLDING, TRANSPORT, & BANQUET CARTS Thermostat Setting 1 2 3 4 5 6 7 8 9 10 Approximate Temperature 100⁰F (37⁰C) 110⁰F (43⁰C) 120⁰F (49⁰C) 130⁰F (54⁰C) 140⁰F (60⁰C) 150⁰F (66⁰C) 160⁰F (71⁰C) 170⁰F (77⁰C) 180⁰F (82⁰C) 190⁰F (88⁰C) F-41140 (09-09) ON / OFF Switch: The ON / OFF Switch supplies electrical power to the cabinet and turns on the fan. The cabinet will not have power unless the switch is in the ON position.
V SERIES FOOD HOLDING, TRANSPORT, & BANQUET CARTS F-41140 (09-09) However, if the film is damaged, the stainless steel can break down and rust. CLEANING WARNING: Always UNPLUG ELECTRICAL POWER SUPPLY before cleaning. DAILY: PREVENTIVE CARE: To prevent stainless steel breakdown, follow these steps: 1. Unplug electrical power supply. 1. 2. Allow warmer to cool before cleaning.
V SERIES FOOD HOLDING, TRANSPORT, & BANQUET CARTS F-41140 (09-09) surface. Then, on a daily basis, apply a high-quality stainless steel polish according to manufacturer’s instructions. To reduce heat tint, limit the exposure of equipment to excessive heat. HEAT TINT: Darkened areas, called “heat tint,” may appear on stainless steel exposed to excessive heat. Excessive heat causes the protective film to thicken. This is unsightly, but is not a sign of permanent damage.
V SERIES FOOD HOLDING, TRANSPORT, & BANQUET CARTS F-41140 (09-09) TROUBLESHOOTING SYMPTOMS Cabinet not operating POSSIBLE CAUSES Check circuit breaker No power. GFCI or Ground Fault Circuit Indicator tripped REMEDY Cabinet not connected to Connect cabinet to power source. power source. ON/OFF switch not ON (VHFA Turn ON/OFF switch ON series) Check GFCI Moisture problem. Dry moisture problem. Shorted element Contact Authorized Service Provider. Pinched/damaged wire.
V SERIES FOOD HOLDING, TRANSPORT, & BANQUET CARTS F-41140 (09-09) SPECIFICATIONS HEIGHT IN (mm) DEPTH IN (mm) WIDTH IN (mm) SHIPPING WT. Lb. (kg) VOLTS WATTS AMPS VB90 71.75" (1822) 42.75" (1086) 31.75" (806) 242# (110 kg) 120 2000 16.6 VB96 62" (1575) 29" (737) 51.5" (1308) 435# (197 kg) 120 2000 16.6 VB150 73" (1854) 29" (737) 61.25" (1556) 590# (268 kg) 120 2000 16.6 VBP5I 31.5" (800) 33.75" (857) 28.25" (718) 170# (77 kg) 120 1200 10 VBP7I 37.75" (959) 33.
V SERIES FOOD HOLDING, TRANSPORT, & BANQUET CARTS WIRING DIAGRAMS 11 F-41140 (09-09)
V SERIES FOOD HOLDING, TRANSPORT, & BANQUET CARTS 12 F-41140 (09-09)
V SERIES FOOD HOLDING, TRANSPORT, & BANQUET CARTS 13 F-41140 (09-09)
V SERIES FOOD HOLDING, TRANSPORT, & BANQUET CARTS 14 F-41140 (09-09)